8
2014 Holiday Rambler Travel Trailer
Appliances - 4
Water Heater Bypass System
A winterization bypass system is installed on
the water heater. The bypass valves are located
behind the water heater.
Winterize the water heater for storage by
removing the drain plug allowing the water
heater to drain. Turn the valves to the Bypass
positions to prevent winterization antifreeze
from entering the tank. When it is time to
resume operation, flush the lines of antifreeze
then turn the valves to Normal Use position to
refill the water heater tank.
Tips
Turn off water heater when not in use
to conserve propane.
When running the shower, conserve the
heated water by shutting the shower
water off when not in immediate use.
The water heater element is
approximately 1500 Watts. When
plugged into 30 Amp shore power
appliances may need to be operated in
sequence to avoid tripping a breaker.
The pressure & temperature relief
valve on the outside of the water heater
is set to open at 210º F. or 150 psi.
When water temperature and pressure
reaches these settings the valve may
drip until pressure has dropped. Do
not open the pressure valve manually.
Replacement valves are available at
most hardware stores.
WARNING:
Before beginning any service or
work on the water heater turn off the
propane connection and disconnect the
120 Volt AC and 12 Volt DC sources.
Failure to do so can result in explosion,
fire or injury.
Troubleshooting
If water heater fails to light, check the
outside burner tube for obstructions.
Spiders or insects may make nests in
the burner tube.
If the water heater indicator light does
not illuminate, and the water heater
does not light, verify the battery is
charged or check for a blown fuse in
the house distribution panel.
If the A/C electric switch does not
light, check the AC source, circuit
breaker or shore cord connection.
The direct spark ignition water heater
must have correct gas pressure and a
DC voltage range between 10.5 Volts
DC and 13.5 DC Volts. This voltage is
supplied directly from the battery or
from the converter.
Due to a possible problem (air or
obstruction) in the propane lines,
the water heater burner will attempt
three ignition cycles. If the burner
does not light after the third attempt,
the propane function will lock-out.
Reasons for lockout may be air in
the propane system or burner tube
obstructions caused by an insect or
spider web. Cycle the water heater
Propane switch off then back on to
reset the ignition board. If problem
persists consult a qualified technician.
040463b
Typical water heater
040427c
Содержание 2014 Aluma-Lite
Страница 10: ...Notes...
Страница 46: ...44 Driving Safety 2 2014 Holiday Rambler Travel Trailer Notes...
Страница 112: ...110 Water Systems 6 2014 Holiday Rambler Travel Trailer Notes...
Страница 124: ...122 2014 Holiday Rambler Travel Trailer Propane Systems 7 Notes...