FM-ONE
HOKUTO DENSHI
CO;LTD;
株式会社
13
Operating tab for V850, 78K0, 78K0R, RL78 families.
Please choose "V850, 78K0, 78K0R, RL78 family" tab to program V850, 78K0, 78K0R, RL78 them.
Boot settings are not needed.
①
Selection of User Program
Select the prepared MOT/HEX file.
Click on the
screen display button of file selection and
then select from among files displayed on Windows.
▼
Those selected files are converted into one project file and
saved in a single HDP file.
▼
If selected files include an write-in address to an area other
than on-chip ROM area good for the boot mode, a warning will
appear.
②
CPU Settings
Select the target MCU from among type names.
Make selection through three stages: Series
→
MCU
name
→
Uart
★
4
.
▼
MCU on the list is a type name which can be available at the
moment. New MCU is now under preparation. For further
information, contact us.
③
Selection of Transmission Rate
★
5
Select a transmission rate between FM
-
ONE and
Target MCU from among the pull-down list.
④
Clook Mode S
ettings
Please input the target
’s clock mode and frequency.
Mode
…Clock Mode (Select from the pull-down list)
Xtal
…Target Clock All MCU is indispensable.
(
When saved in HDP, the frequency is
rounded off to one decimal place.
)
⑤Voltage Setting
Please input the voltage when selecting RL78 family.
(e.g.) 2.5 (e.g.) 5.0
⑥
Other settings
Please refer to
⑤
of page 9 for the details.
⑦
Security Settings
★
6
Reprogramming from the others can be controlled.
Disable Program
Disable Block Erase
Disable Chip Erase
Disable Read
Disable Boot Block Cluster Reprogramming
Flash Shield Window function
Flash Shield Window Start Block
Flash Shield Window End Block
Please select start block and End block to set the window range when
selecting RL78 family.
⑧
Click on SAVE key
Please refer to
⑥
of page 9 for the details.
★
4
Communication form is different in the series of MCU.
Please choose the optional communication form fitted to each series.
Uart
Meaning
UART
x
Serial communication by UART.
CSIB
x
+HS
Serial communication by CSIB+HS(Handshake).
UART_OSC
Serial communication by UART (Uses X1 clock).
UART_FMCLK
Serial communication by UART(Uses the clock of “20-16pin 78K0” which is sold separately).
CSI
x
Serial communication by CSI.
TOOL0
Serial communication by single line UART.
x
:
An optional number
★
5
Boot
…This rate is to be used by combining the target MCU at the time of Start writing. This setting is unnecessary for V850, 78K0, 78K0R
Family.
Async
…This is a rate of an asynchronous communication method when user program data are transmitted. Select a rate with a smaller serial
communications error rate by Target Clock.
▼
Setting value:9600bps
19200bps
31250bps
38400bps
76800bps
115200bps
Sync…This is a rate of a clock synchronized communication method, which is used when the user program data are transmitted.
To use this
rate, SCK signal must be connected to the Target Interface #7.
▼
Setting value: NONE (No need when unnecessary) 10K, 25K, 50k, 100K, 500K, 1M, 2M
★
6 Security Settings are cleared by Chip Erase except for
“Disable Chip Erase” and “Disable Boot Block Cluster Reprogramming”.
In FM-ONE, Chip Erase carried out automatically.
Note: About programming onto V850
・
78K0
・
78K0R series
An option board which fit each series is necessary. As for the details, please refer to the page 20,
”About programming onto
V850
・
78K0
・
78K0R series
”.
①
specify "mot file"
"browse" button
③
Com settings
⑥
Other settings
When saving is in progress,
“
Save
”
is displayed here.
When loading is in progress,
“
Load
”
is displayed
.
④
Clook Mode Settings
⑤
Voltage Setting
⑧
Save
⑦
Security Settings
②
CPU settings
list of series names. list of MCU
names.
Communication form setting