FM-ONE
HOKUTO DENSHI
CO;LTD;
株式会社
12
Operating tab for R8C, M16C, M32R, 740 families.
Please choose "R8C, M16C, M32R, 740 family" tab to program R8C, M16C, M32R, 740.
Boot settings are not needed. but an ID code has to be set in necessary.
Please refer to "IDcode" in hardware manual of each MCU for details.
①
Selection of User Program
Select the prepared MOT/HEX file.
Click on the
screen display button of file selection
and then select from among files displayed on
Windows.
▼
Those selected files are converted into one project file and
saved in a single HDP file.
▼
If selected files include an write-in address to an area
other than on-chip ROM area good for the boot mode, a
warning will appear.
②
MCU Selection
Select the target MCU from among type names.
Make selection through two stages: from the group
selection list to type name list.
▼
MCU on the list is a type name which can be available at
the moment. New MCU is now under preparation. For
further information, contact us.
③
Selection of Transmission Rate
★
2
Select a transmission rate between FM
-
ONE and
Target MCU from among the pull-down list.
④
ID code settings
"FF" is shown in each edit box on choosing MCU
name.
The number of enabled boxes is up to MCU which is
chosen.
⑤
Other settings
Please refer to
⑤
of page 9 for the details.
⑥
Click on SAVE key
Please refer to
⑥
of page 9 for the details.
⑦
Select high-speed programming of
R8C/3x
★
3
,R8C/Lx series
When the voltage is 4.5V
~
5.5V, the programming
speed goes up (please check the box).
★
2
Boot
…This rate is to be used by combining the target MCU at the time of Start writing. This setting is unnecessary for R8C, M16C, M32R, 740
Family.
Async
…This is a rate of an asynchronous communication method when user program data are transmitted. Select a rate with a smaller serial
communications error rate by Target Clock.
▼
Setting value:9600bps
19200bps
38400bps
250Kbps
500Kbps
1Mbps
Sync…This is a rate of a clock synchronized communication method, which is used when the user program data are transmitted.
To use this
rate, SCK signal must be connected to the Target Interface #19.
▼
Setting value: NONE (No need when unnecessary) 10K, 25K, 50k, 100K, 500K, 1M, 2M
★
3 MCU of R8C/32A, 33A, and 35A(354A,355A,356A) can
’t be used.
①
specify "mot file"
"browse" button
list of series names.
list of MCU names.
③
Com settings
⑤
Other settings
When saving is in progress,
“
Save
”
is displayed here.
When loading is in progress,
“
Load
”
is displayed
.
④
ID code settings
⑥
Save
⑦
Select high-speed
programming of R8C/Lx series
②
MCU selection