Hokuto Electronic FLASH2 Скачать руководство пользователя страница 8

HOKUTO DENSHI

 

CO;LTD;

 

  FLASH2     

株式会社

 

 

 

 

Programming Procedure 

 

Operation Flow 

See the following operation flow. In this section, the rest 4 to 8 are explained. 

 

1. Target Board Preparation 

  See 

“User’s Guide” to arrange the target board, where the reference circuit diagrams, interface connection etc.   

2. Control Software Install

 

See the preceding page.

 

3. Connect PC, FLASH2 and Target   

See below.

 

4. Control Software Open 

5. Power supply ON 
6. Parameters 

 

Communication rate and PC port

 

 

MCU type name

 

 

MCU port control status

 

7. Target Program Select 

8. Programming Execute 

Complete                                 

S

S

e

e

e

e

 

 

t

t

h

h

e

e

 

 

f

f

o

o

l

l

l

l

o

o

w

w

i

i

n

n

g

g

 

 

d

d

e

e

s

s

c

c

r

r

i

i

p

p

t

t

i

i

o

o

n

n

s

s

 

 

a

a

b

b

o

o

u

u

t

t

 

 

o

o

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

 

 

p

p

r

r

o

o

c

c

e

e

d

d

u

u

r

r

e

e

s

s

.

.

 

 

 

Control Software Open 

At first, let

’s open the installed control software “F2WinV2”. It can be started to click the name form the pull-up menu 

“start”

 

button at the left bottom of the corner, from 

“program” -> “HokutoDenshi” -> “F2WinV2” then application window 

is opened like below. 
 

 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

The shortcuts assignments for function keys are always indicated on the status-bar and in the pull down menu. 

 

Display Language 

At  the  first  open  of 

“F2WinV2”,  the  display  language  confirmation  is  appeared  automatically.  Select  from  English  and 

Japanese. The selected language can be changed to click the 

“Other” in the “Set” menu. 

 

Power On 

To start the operation, FLASH2 power status must be checked, that is indicated with the UserVCC LED on the 
programmer body. It is necessary to supply both power into programmer itself with AC adapter or alkaline dry 
cells  and  with  UserVcc  from  the  target.  Be  careful  about  the  User  Vcc  voltage  steady  and  properly.  It  is 
important because the FLASH2 uses it as programming voltage to the MCU.

   

7.File Load 

6.Parameter 

8.Excecute 

Version Information 

Shortcut with Function Key 

Power On 

AC adapter or alkaline cells

 

Power   
ON 

PC 

F2WinV2 

Target Board 

FLASH2 

Target Cable 

File-loading can  not  be done without  the  MCU  type 
name selecting. At the file loading, the data address 
is  examined  with  the  selected  MCU  type  name.  If 
MCU type name is need to change, close the loaded 
file at first. 
 
When  this  control  software  is  closed,  all  the 
parameters are save as the file name is 

“flash2.ini”. 

The  control  software  must  be  damaged  if  the  initial 
file 

“flash2.ini” is moved or delete, while the control 

software is opened. 
 
The file box for the third area is indicated only when 
it  is  necessary.  One  box  of  the  upper  step  is 
indicated with the usual MCU. 

Language  select

  dialogue

  is  in  the 

“Display Language” in the menu of “Set.

 

 

 

Содержание FLASH2

Страница 1: ...Procedure 7 Operation Flow 7 Control Software Open 7 Parameters 8 File Loading 9 Execute programming 10 Ending Control Software Operation 10 Programming Expanded Memory of ROM less MCU 10 About progr...

Страница 2: ...bed in this manual by HokutoDenshi Co Ltd and guarantees that the FLASH2 has been produced correctly and is free of any defects per the products specification The FLASH2 is guaranteed for 1 year after...

Страница 3: ...rogrammer FLASH2 Target cable adaptor This AC adaptor is restricted only for Japanese domestic use For direct shipping abroad AC adapter is taken off for safety Instruction manual how to use and Infor...

Страница 4: ...h drycells we recommend to exchange the drycells in every 1 hour for successively programming Programming Voltage 5V or 3 3V depend on VIN that is target Vcc power supply to Interface 18 20pin PC avai...

Страница 5: ...eries contain flexible insulating label to it When placing that kind of batteries into the battery holder negative terminal of the battery holder could come into contact with positive terminal inside...

Страница 6: ...d the signal names How to Purchase the Upgrading Control Software Only upgrading the control software FLASH2 can adapt to every new MCU of Flash memory MCU Microcomputers For the series of single powe...

Страница 7: ...dance to install the MDAC before redo from 1 3 In the next dialogue select install folder confirm the folder where this F2WinV2 install to If it is necessary to change the default directory click the...

Страница 8: ...ge confirmation is appeared automatically Select from English and Japanese The selected language can be changed to click the Other in the Set menu Power On To start the operation FLASH2 power status m...

Страница 9: ...d clock we recommend the serial communication error rate below 0 16 See the bit rate register descriptions in the MCU hardware manual of the chapter about Serial Communications The communication betwe...

Страница 10: ...ters are saved when the control software are closed File Loading Open Close To load the file for programming select Open from the pull down menu in File The MOT HEX file must be named MOT HEX as its e...

Страница 11: ...the flash memory put 0 into here Base Address 4h 7h Bottom of the flash memory put the last address into here Base Address 8h Fh Version of the programming control program Base Address 10h write_init...

Страница 12: ...be appropriately selected 4 Select the port status According to the connections of the interface select the buttons in the port status window to control the target boot mode 5 Check the option flags I...

Страница 13: ...M R8C LA3A LA5A LA6A LA8A R8C LAPS R8C M11A M12A M13B M16C 26 26A 28 29 1N M16C 30P 57 5M 5L M16C 62P 62A 62N 62M M16C 63 64 64A 65 M32C 83 84 85 86 87 R32C 116 118 120 121 R32C 152 153 156 R8C 10 13...

Страница 14: ...scillator of R8C group The following items of MCU group cannot be written by an on chip oscillator R8C10 R8C11 R8C12 R8C13 R8C18 R8C19 R8C1A R8C1B R8C20 R8C21 R8C22 R8C23 R8C24 R8C25 R8C26 R8C27 R8C28...

Страница 15: ...the version 2 1 1 0 Please do the designation of the file referring to the following example path C Program Files x86 FLASH2 F2WinV2 exe o1 XXXX o2 YYYY o3 ZZZZ e The definition of F2WinV2 User Mat o1...

Страница 16: ...ect processing with other appreciations Especially the conflict at the transmission processing will be brought the communication errors Communication error will be also occurred when more than one FLA...

Страница 17: ...ress As acceptable transmission error ratio in serial communications less than 0 16 is recommended If transmission is successes on border at first error can be occurred in progress Unsoldered MCU pins...

Страница 18: ...ns to MCU ports that specified in Renesas Electronics hardware manual for the concerned MCU In the reference circuit diagrams in our the User s Guide we inform the connections including this function...

Страница 19: ...are to upgrade please refer our URL and send E mail to our company Our homepages helps you to confirm the adapted MCU types in the newest version URL http www hokutodenshi co jp E mail support hokutod...