Hokuto Electronic FLASH2 Скачать руководство пользователя страница 12

HOKUTO DENSHI

 

CO;LTD;

 

  FLASH2     

株式会社

 

 

 

11 

 

Programming procedure 

It is the same steps to program the memory except selecting the programming control program. 

1. 

Open the control software, F2WinV2. 

Click twice the icon of 

F2WinV2

2. 

Select the MCU type name 

“H8SX/1650” or “H8SX/1650” 

from the list.   

From 

“MCU  Type”  in  the  menu  of  “Set”,  select    “H8SX/1650”  in  the 

pull-down  list.  Istantly  the  pull-down  box  appears  next  to  it,  to  select  the 
MOT/HEX file of the programming control program. All the MOT/HEX files 
in the specified folder described below are listed in the pull-down list.   

3. 

Select the transfer rate. 

Both initial rate at the beginning of boot mode and maximum rate to 
transfer the user

’s program must be appropriately selected.   

4. 

Select the port status. 

According to the connections of the interface, select the buttons in 
the port status window to control the target boot mode.   

5. 

Check the option flags. 

It is able to set the options, auto erase, fast boot and erase check. 
The optional verifies can be selected here. 

6. 

Load the target file. 

7. 

Click 

“Exec Write” from the menu of “Write”. 

The Directory for the Original Programming Control Program 

The programming control program can

’t be selected, if the MOT/HEX file doesen’t exist in the 

appropriate folders like in the right description.   

Ex. 

C:¥Program Files(x86)¥FLASH 2¥FMWR¥H8Sx1650¥

 

The interface of the target board 

See the description in H8SX/1650 in the User

’s Guide.   

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

Attention

 

The  execution  of  programming  must 
be 

clicked 

after 

selecting 

the 

programming  control  program.  To 
start  programming  without  selecting 
the program can

’t be guaranteed.

   

 

Содержание FLASH2

Страница 1: ...Procedure 7 Operation Flow 7 Control Software Open 7 Parameters 8 File Loading 9 Execute programming 10 Ending Control Software Operation 10 Programming Expanded Memory of ROM less MCU 10 About progr...

Страница 2: ...bed in this manual by HokutoDenshi Co Ltd and guarantees that the FLASH2 has been produced correctly and is free of any defects per the products specification The FLASH2 is guaranteed for 1 year after...

Страница 3: ...rogrammer FLASH2 Target cable adaptor This AC adaptor is restricted only for Japanese domestic use For direct shipping abroad AC adapter is taken off for safety Instruction manual how to use and Infor...

Страница 4: ...h drycells we recommend to exchange the drycells in every 1 hour for successively programming Programming Voltage 5V or 3 3V depend on VIN that is target Vcc power supply to Interface 18 20pin PC avai...

Страница 5: ...eries contain flexible insulating label to it When placing that kind of batteries into the battery holder negative terminal of the battery holder could come into contact with positive terminal inside...

Страница 6: ...d the signal names How to Purchase the Upgrading Control Software Only upgrading the control software FLASH2 can adapt to every new MCU of Flash memory MCU Microcomputers For the series of single powe...

Страница 7: ...dance to install the MDAC before redo from 1 3 In the next dialogue select install folder confirm the folder where this F2WinV2 install to If it is necessary to change the default directory click the...

Страница 8: ...ge confirmation is appeared automatically Select from English and Japanese The selected language can be changed to click the Other in the Set menu Power On To start the operation FLASH2 power status m...

Страница 9: ...d clock we recommend the serial communication error rate below 0 16 See the bit rate register descriptions in the MCU hardware manual of the chapter about Serial Communications The communication betwe...

Страница 10: ...ters are saved when the control software are closed File Loading Open Close To load the file for programming select Open from the pull down menu in File The MOT HEX file must be named MOT HEX as its e...

Страница 11: ...the flash memory put 0 into here Base Address 4h 7h Bottom of the flash memory put the last address into here Base Address 8h Fh Version of the programming control program Base Address 10h write_init...

Страница 12: ...be appropriately selected 4 Select the port status According to the connections of the interface select the buttons in the port status window to control the target boot mode 5 Check the option flags I...

Страница 13: ...M R8C LA3A LA5A LA6A LA8A R8C LAPS R8C M11A M12A M13B M16C 26 26A 28 29 1N M16C 30P 57 5M 5L M16C 62P 62A 62N 62M M16C 63 64 64A 65 M32C 83 84 85 86 87 R32C 116 118 120 121 R32C 152 153 156 R8C 10 13...

Страница 14: ...scillator of R8C group The following items of MCU group cannot be written by an on chip oscillator R8C10 R8C11 R8C12 R8C13 R8C18 R8C19 R8C1A R8C1B R8C20 R8C21 R8C22 R8C23 R8C24 R8C25 R8C26 R8C27 R8C28...

Страница 15: ...the version 2 1 1 0 Please do the designation of the file referring to the following example path C Program Files x86 FLASH2 F2WinV2 exe o1 XXXX o2 YYYY o3 ZZZZ e The definition of F2WinV2 User Mat o1...

Страница 16: ...ect processing with other appreciations Especially the conflict at the transmission processing will be brought the communication errors Communication error will be also occurred when more than one FLA...

Страница 17: ...ress As acceptable transmission error ratio in serial communications less than 0 16 is recommended If transmission is successes on border at first error can be occurred in progress Unsoldered MCU pins...

Страница 18: ...ns to MCU ports that specified in Renesas Electronics hardware manual for the concerned MCU In the reference circuit diagrams in our the User s Guide we inform the connections including this function...

Страница 19: ...are to upgrade please refer our URL and send E mail to our company Our homepages helps you to confirm the adapted MCU types in the newest version URL http www hokutodenshi co jp E mail support hokutod...

Отзывы: