5. Example of wiring diagram.
Please refer to the indoor unit installation manual to find detailly how to set and check the communication
address.
Incorrect address setting will cause abnormal to the system.
6. After installation, please fill in the following table for easy daily maintenance:
Indoor unit NO.
A
B
C
D
Model of indoor unit
Serial no.
Room name
Wiring work
The distance between the signal wires and the power cab
l
es should be at least 50mm.
C
B
A
Q
P
1(L) 2(N)
2(N)
1(L)
P
Q
A
B
C
L N
C1 C2
To other
indoor unit
To outdoor unit
(P
,
Q)
Waring:
1.
Incorrect address setting will cause abnormal to the system.
2.
Communication cable must be use shi
e
lded type.
Communication cable (Shield wire):
H05RN-F 2X1.5 mm
2
Power cable : H05RN-F 3G 2.5 mm
2