DUST FILTER
The Indoor Unit is equipped with a high-efficency filter which do grant a higher comfort and a
healthy air quality inside the room.
INFRARED REMOTE CONTROLLER
All available functions of the air conditioner must be set using the infrared remote controller,
whose LCD panel shows immediately the operating parameters.
ON TIMER / OFF TIMER
ON Timer,
allows to program the air conditioner start within 24 hours. TIMER ON is set by 1
hour’s steps.
OFF Timer
, allows to program the air conditioner stop within 24 hours. TIMER OFF is set 1
hour’s steps.
DRY FUNCTION
When “DRY” function is selected, the air conditioner strongly reduces humidity inside the room,
and also keeps the room temperature at a constant value.
ADVANCED CONTROL FOR INDOOR UNIT FAN
Thermostatic stops.
In Heating mode, when set temperature has been reached inside the
room, the compressor stops and the indoor fan speed is lowered to avoid cold drafts.
Hot Keep.
At the beginning of operation in Heating mode, the indoor fan will start only 5 minutes
later, i.e. when the temperature of indoor heat exchanger is adequate.
“SLEEP” FUNCTION (ENERGY SAVING MODE)
It consists in automatic and gradual correction of the differential between the room temperature
and the set temperature. This avoids the Unit to operate continuously at peak capacity for long
periods.
“TURBO” FUNCTION
This Inverter Model of air conditioner is provided with Turbo function, which can be activated
by pressing TURBO button.
MICROCOMPUTER CONTROLLED DEFROSTING FUNCTION (HEATING MODE)
When the outdoor air temperature is very low and humidity is very high, frosting will occur to
the heat exchanger of the Outdoor Unit, which has negative impacts upon the efficiency of the
heating performance. In such case, the automatic defrosting function will come into play. The
Heating operation will be stopped for 5-10 minutes to do the defrosting.