Calibration instructions
geodyna 6300
Page 3 of 8
Date 2 Oct 2001
Measuring adaptor flange and zero plane using code C81.
Service and test functions become accessible by simultaneously pressing and
holding the C and the balancing mode keys and by rotating the main shaft.
The following reading appears:
Apply the gauge arm on the contact surface of the test rotor and press the C
key to store the value.
The following reading appears:
Calibration is completed and must be stored by entering C90.
C 81.
C - -
1. 0