Calibration instructions
geodyna 6300
Page 1 of 8
Date 2 Oct 2001
Basic settings of diameter and distance potentiometers with code
C80
Service and test functions become accessible by simultaneously
pressing and holding the C and the balancing mode keys and by
rotating the main shaft.
… is read out for 1 second.
The display proceeds automatically to the basic settings.
Then the basic settings of .15 to .2 Volt of the diameter and distance
potentiometers are read out.
The left-hand reading refers to the basic setting of the diameter potentiometer.
Engage the calibration tip of the gauge head with the calibration groove in the
board of the vibratory system. If the slider voltage of the diameter potentiometer
is not within a range of .15 to .20 Volt, turn the potentiometer shaft to bring the
voltage to within this range.
The right-hand reading refers to the basic setting of the distance potentiometer.
If the gauge arm is in left home position and if the slider voltage of the distance
potentiometer is not within a range of .15 to .20 Volt, turn the potentiometer
shaft to bring the voltage to within this range.
Return the gauge arm into the left home position and press the C key to store
the values.
The following reading appears:
Fully pull out the gauge arm, hold, and press the C key to store the value.
The following reading appears:
Engage the calibration tip on the bottom of the gauge head with the calibration
groove in the board of the vibratory system and press the C key to store the
value.
C80.
1.
0,17 0,16
2 0,16
3 0,16