Instruction manual
No. 2117-3e
2.98
2.
Operation
2.1.
Switch on the unit by means of the pull switch "power" on the rear panel of the
unit.
For more information on the pull switch, see also chapter "Meter counter".
2.2.
Tachometer / meter counter
Switch located below the LCD set to:
Σ
m
Length of marked line will be displayed.*
km/h
Travelling speed will be displayed.
*
By switching over to
Σ
m, the accumulated counting for the line
length will be shown on the display.
REMARK:
Whenever the magnetic valves are in operation (i.e. when a gun is activated),
never remove the gun connector from the unit. The memory contents for the
meter counter could be falsyfied or be completely lost. The figure 100 may
appear on the display.
By switching the unit on and off, you can make it operable and set the meter
counter back to zero.
Or:
Set the "Start-Stop" switch to "Stop" and then back to "Start", whereby the meter
counter is not set back to zero.