HIT-4 Communication Program 53
HIT-4U
HP-327
Data Logs
The HIT-4 records flow data into hourly and daily logs. Each log entry
contains a Date/Time stamp, Total Flow and Run Time. The Run Time is
the duration of flow in seconds recorded during the log interval. The
maximum Run Time for an hourly log is 3600 and 86400 for a daily log.
The data can be viewed in tabular, graph, save to file, print logs, and to
export log data into an Excel spreadsheet. In addition the Event log allows
the user to identify changes to the configuration parameters.
The Flow Logs and Event Log can be downloaded from the HIT-4 by
clicking on the “Logs” in the menu bar.
The “New Data Logs” field will display the number of new “Hourly
Logs”, “Daily Logs” and “Event Log”.
Logs are downloaded by clicking on the drop down “Select Log” box, and
selecting the desired log to be downloaded. Once the selection has been
made, either click on the “Download New” or “Download All” menu
options.