background image

User Access Levels | 11

Version 1.04 | May 2019 | MAN-1432HA

Содержание FIRENET L@TITUDE

Страница 1: ...FIRENET L TITUDE FIRE ALARM CONTROL PANEL OPERATING INSTRUCTIONS Version 1 04 May 2019 MAN 1432HA...

Страница 2: ...6 User Access Levels 8 No User Group 9 User Access Level 2 10 User Access Level 3 10 Controls 12 No User Group 12 System Information 13 Panel Tests 14 User Access Level 2 15 System Information 15 Disa...

Страница 3: ...al Information 26 Operating Instructions 26 Inspecting Batteries 26 Replacing Standby Batteries 26 Related Documentation 26 Troubleshooting 28 Contact Information 30 Emergency Contact 30 Service Conta...

Страница 4: ...s will numerically indicate active events on the panel the active event type with the highest priority will automatically be displayed Any event type can be accessed by pressing the associated tab Mon...

Страница 5: ...InterpretingPanel Information 5 Panel LEDs For complete information about each event type refer to Section 1 Events and Status Version 1 04 May 2019 MAN 1432HA...

Страница 6: ...ire In Zone Indicators Fire In Zone indicators are an optional feature provided on the fascia of the FireNET L titude Fire Alarm Control Panel in single double or triple bank configurations The follow...

Страница 7: ...InterpretingPanel Information 7 Version 1 04 May 2019 MAN 1432HA...

Страница 8: ...May 2019 MAN 1432HA USER ACCESS LEVELS FIRE SYSTEM NORMAL The Fire System Normal display is visible on the panel GUI when operating in quiescent standby mode Control buttons will appear on the panel...

Страница 9: ...s are restricted when operating the fire control panel in the No User Group This level allows users to view system information and to perform simple tests It also provides options for testing LED indi...

Страница 10: ...rd Refer to User Access Level 2 for specific feature details NOTE When using a panel with a Plex Door Enclosure User Access Level 2 is achieved by using the key to open the door User Access Level 3 Us...

Страница 11: ...User Access Levels 11 Version 1 04 May 2019 MAN 1432HA...

Страница 12: ...Controls 12 Version 1 04 May 2019 MAN 1432HA CONTROLS No User Group...

Страница 13: ...Controls 13 System Information Version 1 04 May 2019 MAN 1432HA...

Страница 14: ...st The internal buzzer of the fire control panel sounds and all indicator lamps light for 5 seconds Contact Technical Support if fascia lamps do not light DISPLAY TEST This test confirms operation of...

Страница 15: ...Controls 15 User Access Level 2 The User Options menus are as shown System Information Refer to No User Group System Information Version 1 04 May 2019 MAN 1432HA...

Страница 16: ...disablements can be performed from this window Press the desired button for options when performing that specific disablement To view the disablement and or re enable it press the Disablement tab All...

Страница 17: ...alarm delay if the responding party manually silences the alarm at the control panel This action provides time to investigate an alarm before evacuating a building To disable the positive alarm press...

Страница 18: ...view of the available zones 4 Press Submit Select Yes or No for the NACs On field and press Submit to test the zones The zone s will be tested and the appropriate LEDs will light To view the test and...

Страница 19: ...et Date Time SET DATE TIME Use this option to set the date and time Use the arrows to increase or decrease the value for each field or press the field to manually enter a new value Version 1 04 May 20...

Страница 20: ...View Event Log VIEW EVENT LOG This option displays the panel event log l Press More Details to display additional information about the selected event l Press More Options to filter the results by ev...

Страница 21: ...Devices VIEW DEVICES To view the connected devices press View Devices and select the desired Loop or Zone to view the connected devices Panel Tests Refer to No User Group Panel Tests Version 1 04 May...

Страница 22: ...n the panel press GUI Settings The following options are available Dim screen with ambient light Yes No Buzz buzzer on screen touch Yes No Keyboard Language NOTE Only available if your panel has been...

Страница 23: ...Controls 23 Version 1 04 May 2019 MAN 1432HA...

Страница 24: ...on silences the internal buzzer and all notification appliances as programmed This will not affect the GUI display or LED indicators Re sound Alarms Press Re sound Alarms to reactivate the internal bu...

Страница 25: ...he event To reset the fire control panel from the latching input 1 Clear alarm conditions from external devices 2 Press Reset System to reset the latching events and restore the panel to the Normal St...

Страница 26: ...determine their suitability for continued standby operation Replacing Standby Batteries Replace standby batteries when the service period reaches 3 to 5 years or when the low battery message is presen...

Страница 27: ...General Information 27 Version 1 04 May 2019 MAN 1432HA...

Страница 28: ...ected on the network that is not in the configuration This is a configuration error and should never occur once the network has been properly configured Network Card Missing This event indicates that...

Страница 29: ...dicates a wiring error or damage to the wires connecting the panel to its neighbor Full Open Circuit Trouble This event indicates that an open circuit has been detected by the link impedance measureme...

Страница 30: ...CONTACT INFORMATION Emergency Contact Contact the company or individual responsible for providing assistance in the event of an emergency In the event of an emergency notify Name Company Primary Tele...

Страница 31: ...formation 31 Service Contact Contact the company or individual responsible for providing service Name Company Primary Telephone Secondary Telephone Cell Phone Address City State Version 1 04 May 2019...