background image

NSW

 02 9644 7144    

QLD

 07 3252 5366    

VIC

 03 9544 2211   

WA

 08 9349 2972

FIREbeam Xtra User Manual 

10 

2-3-0-2700/ISS2/21.OCT19

More power will be output than is necessary to cover the distance and these levels will then 
be reduced once the auto align process takes place.  The air quality figure at this point 
should normally stay at 0%.  Pre-Align Complete will now be indicated. 

Press enter to accept Pre-Alignment and confirm these settings by pressing the right key and 
enter into Manual Alignment. 

The FIREbeam Xtra is looking for the far wall of the building and in some shorter distance 
applications will stop raising the IR Power when it’s sufficient for the distance.  In these 
cases, you can press Enter to accept the Pre-Alignment then the right key and enter into 
Manual Alignment. 

CAUTION: If you have not allowed the 50cm radius and the beam encounters an obstruction 
this will also stop raising the IR Power and halt the Pre-Alignment as the beam will assume it 
has found the far wall.   

You will need to identify and move the obstruction or reconsider the positioning of the beam. 
You can identify that the beam is obstructed if the right-hand figure (Air Quality) has risen 
and is fluctuating between 5%-10%. 

Obstructions near the head will disturb the pre-alignment process and care should be taken 
to ensure no solid objects are close to the beam path. 

Содержание FIREbeam Xtra

Страница 1: ...USER GUIDE FIREbeam Xtra Reflective Optical Beam Smoke Detector NSW 02 9644 7144 QLD 07 3252 5366 VIC 03 9544 2211 WA 08 9349 2972...

Страница 2: ...ra Long Range 140 to 160m Kit 3 Position 4 Installing Commissioning and Testing 5 Step 1 Mounting the Head 5 Step 2 Mounting the Controller 6 Wiring Configuration 7 Step 3 Programming the Analogue Add...

Страница 3: ...ingle reflector 7 to 70 metres the standard FIREbeam Xtra The standard FIREbeam Xtra comes boxed with the head unit low level controller one reflector short range mask 3mm Allen key and quick start in...

Страница 4: ...to 0 6m down from the top of the apex up to a maximum height of 40m from the floor The maximum protected area either side of the beam can be extended by 1 for every degree of roof pitch see the examp...

Страница 5: ...the beam care should be taken when mounting in glass atriums Ambient sunlight will not affect the beam Also available Unistrut adapter plate Use this accessory for easy mounting to Unistrut fabricatio...

Страница 6: ...IMPORTANT ensure the connector is this way up Screw the head screws down with the 3mm allen key provided Your wiring should be flush and not flattened by tightening down screws Step 2 Mounting the Co...

Страница 7: ...rol panel documentation on how to program this functionality Step 3 Programming the Analogue Address The FIREbeam Xtra is programmed via the integral Control Module situated on the main PCB within the...

Страница 8: ...ey provided Your wiring should be flush and not flattened by tightening down screws Step 4 Commissioning Commissioning the FIREbeam Xtra is a simple procedure outlined in the following step by step ex...

Страница 9: ...ent excessive current draw Fast mode allows x 4 times faster motor response and it may be quicker to commission each beam in turn Once commissioning is complete the FIREbeam Xtra will automatically re...

Страница 10: ...distance applications will stop raising the IR Power when it s sufficient for the distance In these cases you can press Enter to accept the Pre Alignment then the right key and enter into Manual Align...

Страница 11: ...hen you install or uncover the reflector the right hand Figure AQ will jump up as high as 135 this clearly shows that the beam can see the reflector and you can press Enter to move to Auto Alignment I...

Страница 12: ...e beam is on the reflector In the example above moving the y axis down y results in a greater AQ Try and achieve as high an AQ as possible it must be at least 80 to 100 ideally above 100 Once you have...

Страница 13: ...Fault Note The beam must be tested at the reflector end and not at the beam head This is to confirm it is looking at the reflector and completes the commissioning process FAULT Cover the reflector wi...

Страница 14: ...to normal automatically See the menu system on the following pages on how to change between auto and latching if required FAULT The beam path has been fully blocked within 1 second used when fault tes...

Страница 15: ...nts to the beam Select this option to carry out routine maintenance Select this option to access power and temperature headings Individual Menu Items Language The language is factory set to English as...

Страница 16: ...m will reach full power and the screen will say Pre Align complete If you don t receive high enough output power and receiver sensitivity readings this will usually be because you are receiving a refl...

Страница 17: ...y set to auto reset when the received signal raises above the fire threshold hysteresis This can be set to latching if your system requires this Change by using the right and left keys Press enter to...

Страница 18: ...times you can choose between 0 default setting and 6 Press enter to return to Mode Change or down to go to Hysteresis Hysteresis Changing the hysteresis will change the delay in returning from a fire...

Страница 19: ...beam Press enter to return to Beam Maintenance or down to go to Alarm Fault Event Counts Alarm Fault Event Counts Here we can see how many times the beam has gone into fire or fault since the beam was...

Страница 20: ...r decreased by using the right and left keys Press enter to return to Diagnostics or down to go to RX Sensitivity RX Sensitivity This screen shows the receiver sensitivity and can be changed by using...

Страница 21: ...ed and terminated Mechanical Specifications Beam Head 180 mmH x 155 mmW x137 mmD Weight 1 1Kg Controller 185 mmH x 120 mmW x 62 mmD Weight 0 55g 70KIT140 Mid Range Reflector 293 mmH x 293 mmW x 5 mmD...

Страница 22: ...o reset connections in Beam Head Fault Sensitivity Level 4 Fault Condition Obscuration drops to below the fault sensitivity level within 1 second Power Down or Supply Voltage 9 VDC Commissioning modes...

Страница 23: ...ress 19 Halley Road BALCATTA WA 6021 Phone 08 9349 2972 Email saleswa incitefire com au Melbourne Address Unit 120 45 Gilby Road MT WAVERLEY VIC 3149 Phone 03 9544 2211 Fax 03 9544 2212 Email salesvic...

Отзывы: