3.

 

Make sure the solar panel cable is plugged in. 

 

The mote contacts the network once the new batteries are 

installed. The green LED blinks quickly while the mote searches 

for a network to join and then blinks slowly while it completes 

the network registration. Once the mote has finished joining 

the network, the green LED turns off and the blue LED then 

blinks indefinitely while the mote is part of the network. 

Lithium Batteries 

You can use two 1.5 V lithium batteries (HWSB-LI) for operation 

at the extreme ends of the mote operating range. Lithium 

battery life is an estimated at 1 year, but varies based on the 

ambient temperature where the mote is deployed, the logging 

interval, the number of tripped alarms, and other factors. 

Estimates are not guaranteed due to uncertainties in initial 

battery conditions and operating environment. When using 

lithium batteries, you must disconnect the solar panel cable 

because the batteries will not be recharged. 
To install lithium batteries: 
1.

 

Open the mote door. 

2.

 

Remove any old batteries and install the new ones 

observing polarity. 

3.

 

Push in the side tab of the solar panel cable connector and 

pull the connector out of the cable port. 

4.

 

Place the connector in the slot on the inside of the mote 

door. Make sure the solar panel cables are tucked inside the 

door so that they do not interfere with the interior seal 

when the mote is closed. 

 

The mote contacts the network once the new batteries are 

installed. The green LED blinks quickly while the mote searches 

for a network to join and then blinks slowly while it completes 

the network registration. Once the mote has finished joining 

the network, the green LED turns off and the blue LED then 

blinks indefinitely while the mote is part of the network. 

 

WARNING:

 Do not cut open, incinerate, heat above 85°C 

(185°F), or recharge the lithium batteries. The batteries may 

explode if the mote is exposed to extreme heat or conditions 

that could damage or destroy the battery cases. Do not mix 

battery types, either by chemistry or age; batteries may rupture 

or explode. Do not dispose of the logger or batteries in fire. Do 

not expose the contents of the batteries to water. Dispose of 

the batteries according to local regulations for lithium 

batteries.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Store the solar 

panel connector 

here when using 

lithium batteries 

Make sure 

solar panel 

cable is 

installed 

when using 

rechargeable 

batteries 

Содержание RXW TEROS-12

Страница 1: ...m Wireless Mote Operating Temperature Range Sensor 40 to 60 C 40 to 140 F Mote 25 to 60 C 13 to 140 F with rechargeable batteries 40 to 70 C 40 to 158 F with lithium batteries Radio Power 12 6 mW 11...

Страница 2: ...he mote batteries see Deploying and Mounting Sensor Cable This is the cable that connects the mote to the sensor Eyelet Use this eyelet to attach a 3 16 inch padlock to the mote for security Latch Use...

Страница 3: ...an embedded thermistor A ferrite core positioned on the sensor cable 7 6 cm 3 inches away from the sensor head is used to isolate the sensor from any interferences in the system This mitigates any pot...

Страница 4: ...HOBOlink and report the mote as missing Once the mote is back online any logged data will be uploaded the next time the station connects to HOBOlink See the HOBOlink Help for details on how to change...

Страница 5: ...are contaminated with oils from contact with skin or another source follow the instructions in the Maintenance section for cleaning the needles before installing the sensor Avoid any metal located bet...

Страница 6: ...load the file to your computer 5 In HOBOlink go to Devices then RX Devices and click your station name 6 On the station page click Overview and scroll down to Device Information 7 Click the Wireless t...

Страница 7: ...ll the new ones observing polarity 3 Push in the side tab of the solar panel cable connector and pull the connector out of the cable port 4 Place the connector in the slot on the inside of the mote do...

Страница 8: ...uding interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate...

Отзывы: