Hobo RXW TEROS-12 Скачать руководство пользователя страница 2

RXW TEROS-12 Soil Moisture EC Temp Sensor (RXW-T12-xxx) Manual 

1-800-LOGGERS 

www.onsetcomp.com 

Specifications (continued) 

Dimensions 

Sensor: 7.47 x 9.4 x 2.39 cm (2.94 x 3.7 x 0.94 inches) 

Sensor needle length: 5.4 cm (2.13 inches) 

Sensor needle diameter: 0.32 cm (0.13 inches) 

Cable length: 5 m (16.4 ft) 

Mote: 16.2 x 8.59 x 4.14 cm (6.38 x 3.38 x 1.63 inches) 

Weight 

RXW-T12-xxx sensor and cable: 245

 

grams (8.64

 

oz) 

Mote: 223 g (7.87 oz) 

Materials 

Sensor: ASA plastic body with polyurethane epoxy filling and stainless steel 

pins 
Cable: PVC, UV resistant and rodent repellent 

Mote: PCPBT, silicone rubber seal 

Environmental Rating 

Mote: IP67, NEMA 6 

Compliance Marks 

 

RXW-T12-900: See last page 

 

 

RXW-T12-868: The CE Marking identifies this product as 

complying with all relevant directives in the European Union 

(EU). 

 

 

RXW-T12-921: See last page 

 

 

RXW-T12-922: See last page 

*  The sensor data can be post-calibrated if necessary (e.g. the sensor is used in non-mineral soil types or higher than 

standard accuracy is required). Users can apply a calibration equation to the data exported from HOBOlink. The VWC 

range will depend on the calibration equation. 

** Temperature measurement, for applicable sensors, may not be accurate if sensor is not fully immersed in medium of 

interest, due to longer equilibration time. 

Mote Components and Operation 

 

 

Sensor Mote Closed, Front 

Sensor Mote Closed, Back 

 

 

Sensor Mote Opened 

Mounting Tab:

 Use the tabs at the top and bottom of the mote 

to mount it (see 

Deploying and Mounting

). 

Solar Panel:

 Position the solar panel towards the sun to charge 

the mote batteries (see 

Deploying and Mounting

). 

Sensor Cable:

 This is the cable that connects the mote to the 

sensor. 

Eyelet:

 Use this eyelet to attach a 3/16 inch padlock to the 

mote for security. 

Latch:

 Use the two latches to open and close the mote door. 

Ground Wire Port: 

Use this port to connect a ground wire (see 

Deploying and Mounting

). 

Antenna:

 This is the built-in antenna for the radio 

communications across the RX Wireless Sensor Network.

 

LEDs: 

There are two LEDs to the left of the LCD screen. The 

green LED blinks during the process of joining a network, 

blinking quickly while the mote searches for a network and 

then slowly as the mote registers with the network. Once the 

network registration process is complete, the blue LED blinks at 

4 seconds to indicate normal operation. If the mote is not 

currently part of a network, the blue LED will be off. If the blue 

LED is on and not blinking, there is a problem with the mote. 

Contact Onset Technical Support.

 

Solar Panel Cable:

 This cable connects the built-in solar panel 

to the mote circuitry. 

Battery Holder:

 The location where the batteries are installed 

as shown (see 

Battery Information

). 

USB Port: 

Use this port to connect to the mote to a computer 

via USB cable if you need to update the firmware (see 

Updating 

Mote Firmware

).

 

Button:

 Push this button for 1 second to illuminate the LCD or 3 

seconds for the mote to search for a HOBOnet Wireless Sensor 

Network to join (see 

Adding the Mote to the HOBOnet Wireless 

Sensor Network

). 

LCD Screen:

 The mote is equipped with an LCD screen that 

displays details about the current status. The following example 

Mounting 

Tab 

Solar Panel 

Latch 

Eyelet 

Ground Wire 

Port 

Sensor Cable 

Solar Panel Cable 

Button 

USB Port 

Battery Holder 

LCD Screen 

Antenna 

LEDs 

Содержание RXW TEROS-12

Страница 1: ...m Wireless Mote Operating Temperature Range Sensor 40 to 60 C 40 to 140 F Mote 25 to 60 C 13 to 140 F with rechargeable batteries 40 to 70 C 40 to 158 F with lithium batteries Radio Power 12 6 mW 11...

Страница 2: ...he mote batteries see Deploying and Mounting Sensor Cable This is the cable that connects the mote to the sensor Eyelet Use this eyelet to attach a 3 16 inch padlock to the mote for security Latch Use...

Страница 3: ...an embedded thermistor A ferrite core positioned on the sensor cable 7 6 cm 3 inches away from the sensor head is used to isolate the sensor from any interferences in the system This mitigates any pot...

Страница 4: ...HOBOlink and report the mote as missing Once the mote is back online any logged data will be uploaded the next time the station connects to HOBOlink See the HOBOlink Help for details on how to change...

Страница 5: ...are contaminated with oils from contact with skin or another source follow the instructions in the Maintenance section for cleaning the needles before installing the sensor Avoid any metal located bet...

Страница 6: ...load the file to your computer 5 In HOBOlink go to Devices then RX Devices and click your station name 6 On the station page click Overview and scroll down to Device Information 7 Click the Wireless t...

Страница 7: ...ll the new ones observing polarity 3 Push in the side tab of the solar panel cable connector and pull the connector out of the cable port 4 Place the connector in the slot on the inside of the mote do...

Страница 8: ...uding interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate...