TM-258 267 Page 18
Handler 140
SECTION 7
−
TROUBLESHOOTING
7-1. Troubleshooting Table
.
See Section 7-2 for test points and values and
Section 10 for parts location.
.
Use Miller Testing Booklet (Part No. 150 853)
when servicing this unit.
.
See the Miller Extranet for service memos that
may aid in the repair of this product.
Trouble
Remedy
No weld output; wire does not feed; fan
does not run.
Secure power cord plug PLG1 in receptacle (see Section 4-7).
Replace building line fuse or reset circuit breaker if open.
Place Power switch S1 in On position (see Section 5-1).
Reset power source supplementary protector if open (see Section 8-2).
No weld output; wire does not feed; fan
runs.
Check Voltage switch S2 position. Rotate knob until it “clicks” into detent at desired range setting.
Thermostat TP1 open (overheating). Allow fan to run; the thermostat will close when the unit has
Secure gun trigger leads to receptacle RC3 (see Section 4-2).
Check continuity of gun trigger leads. Repair or replace gun if necessary.
Check continuity of Voltage switch S2, and replace if necessary.
Check diodes in main rectifier SR1, and replace if necessary.
Check main transformer T1 for signs of winding failure. Check continuity across windings and check for
proper connections. Check secondary voltages. Replace T1 if necessary.
Check control board PC1 connections and voltages, and replace if necessary.
Electrode wire feeding stops during
welding.
Straighten gun cable and/or replace damaged parts (see Section 8-6).
Readjust drive roll pressure (see Section 4-11).
Change to proper drive roll groove (see Section 8-4).
Readjust wire reel hub tension (see Section 4-9).
Replace contact tip if blocked (see Section 8-5).
Clean or replace wire inlet guide or liner if dirty or plugged (see Section 8-4 and/or 8-6).
Replace drive roll or pressure bearing if worn or slipping (see Section 8-4).
Secure gun trigger leads in receptacle RC3 (see Section 4-2).
Check continuity of gun trigger leads. Repair or replace gun if necessary.
Check and clear any restrictions at drive assembly and liner (see Section 8-4 and/or 8-6).
Release gun trigger and allow gun and motor protection circuitry to reset.
Check T1 for signs of winding failure. Check continuity across each winding and check for proper
connections. Check secondary voltages. Replace T1 if necessary.
Check Control board PC1 and connections, and replace PC1 if necessary (see Section 7-3).
Содержание H100S2-10
Страница 17: ...TM 258 267 Page 15 Handler 140 5 2 Weld Parameter Chart 258 069 A ...
Страница 30: ...TM 258 267 Page 28 Handler 140 Notes ...
Страница 32: ...TM 258 267 Page 30 Handler 140 Figure 9 1 Circuit Diagram Eff w MC370275Y And Following ...
Страница 33: ...TM 258 267 Page 31 Handler 140 257 502 A ...
Страница 34: ...TM 258 267 Page 32 Handler 140 Figure 9 2 Wiring Diagram Eff w MC370275Y And Following ...
Страница 35: ...TM 258 267 Page 33 Handler 140 257 500 A ...
Страница 38: ...TM 258 267 Page 36 Handler 140 Notes ...
Страница 45: ...Notes ...
Страница 46: ...Notes ...
Страница 47: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual ...