TM-258 267 Page 21
Handler 140
Voltage Readings
a)
Tolerance
−
10 % unless
specified
b)
Wiring Diagram
−
V1
115 volts AC with power cord plugged in
V2
115 volts AC with Power switch S1 On
V3
24 volts AC with Power switch S1 On
V4
30 volts DC with Power switch S1 On
V5
24 volts AC with gun trigger closed with Power
switch S1 On
V6
14.0 volts AC with unit turned on, Voltage switch S2
in position 1 and gun trigger closed
15.6 volts AC with unit turned on, Voltage switch S2
in position 2 and gun trigger closed
17.2 volts AC with unit turned on, Voltage switch S2
in position 3 and gun trigger closed
18.7 volts AC with unit turned on, Voltage switch S2
in position 4 and gun trigger closed
20.2 volts AC with unit turned on, Voltage switch S2
in position 5 and gun trigger closed
V7
14.0 volts AC with unit turned on, Voltage switch S2
in position 1 and gun trigger closed
15.6 volts AC with unit turned on, Voltage switch S2
in position 2 and gun trigger closed
17.2 volts AC with unit turned on, Voltage switch S2
in position 3 and gun trigger closed
18.7 volts AC with unit turned on, Voltage switch S2
in position 4 and gun trigger closed
20.2 volts AC with unit turned on, Voltage switch S2
in position 5 and gun trigger closed
V8
18.7 volts DC with unit turned on, Voltage switch S2
in position 1 and gun trigger closed
20.7 volts DC with unit turned on, Voltage switch S2
in position 2 and gun trigger closed
23.0 volts DC with unit turned on, Voltage switch S2
in position 3 and gun trigger closed
25.1 volts DC with unit turned on, Voltage switch S2
in position 4 and gun trigger closed
27.4 volts DC with unit turned on, Voltage switch S2
in position 5 and gun trigger closed
V9
115 volts AC with unit turned on and gun trigger
closed
V10
2.9 to 15.4 volts DC with unit turned on, Wire Speed
control R2 from min. to max. with Voltage switch S2
in position 1
3.7 to 17.5 volts DC with unit turned on, Wire Speed
control R2 from min. to max. with Voltage switch S2
in position 2
4.5 to 19.9 volts DC with unit turned on, Wire Speed
control R2 from min. to max. with Voltage switch S2
in position 3
5.2 to 22.0 volts DC with unit turned on, Wire Speed
control R2 from min. to max. with Voltage switch S2
in position 4
5.9 to 23.6 volts DC with unit turned on, Wire Speed
control R2 from min. to max. with Voltage switch S2
in position 5
Voltage
Switch S2
Position
Min.
IPM
Max.
IPM
1
2
3
4
55
75
97
118
412
500
528
586
Wire Diameter
And Type
*All tests done with .030 solid wire, .030-.035 liner in
H-100 model 10 foot welding gun, smooth groove
drive roll.
Values are nominal depending on drive roll pressure
and spool hub tension.
Resistance Values
a) Tolerance
−
10% unless specified
b) Turn Off unit and disconnect input
power before checking resistance
R1-R8 All values for T1 are less than 1 ohm
R9
Less than 1 ohm with gun trigger pressed,
high resistance with gun trigger open
R10
Less than 1 ohm
R11
Less than 1 ohms at minimum position of
Wire Speed control R2, 50k ohms at
maximum position of R2
.030/.035 Solid
or Flux Core
230 952-A
Wire Speed While Feeding*
Min.
RPM
Max.
RPM
1
2
3
4
22
29
35
40
123
141
160
176
*All tests done with the pressure assembly
open, not feeding wire. Values are nominal.
Drive Motor RPM At No Load*
Voltage
Switch S2
Position
5
134
704
5
43
187
Содержание H100S2-10
Страница 17: ...TM 258 267 Page 15 Handler 140 5 2 Weld Parameter Chart 258 069 A ...
Страница 30: ...TM 258 267 Page 28 Handler 140 Notes ...
Страница 32: ...TM 258 267 Page 30 Handler 140 Figure 9 1 Circuit Diagram Eff w MC370275Y And Following ...
Страница 33: ...TM 258 267 Page 31 Handler 140 257 502 A ...
Страница 34: ...TM 258 267 Page 32 Handler 140 Figure 9 2 Wiring Diagram Eff w MC370275Y And Following ...
Страница 35: ...TM 258 267 Page 33 Handler 140 257 500 A ...
Страница 38: ...TM 258 267 Page 36 Handler 140 Notes ...
Страница 45: ...Notes ...
Страница 46: ...Notes ...
Страница 47: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual ...