6.
Run-in and Periodic Check
a. Mount the engine-generator assembly in a suitable test area and operate it for a 2-hour run-in.
b. Shut down the engine after 2 hours and re-torque all coupling screws to 40 - 45 foot-pounds (54 -
61 Nm) to compensate for normal torque relaxation.
c. Return the unit to normal service.
d. After 200 hours of operation, check all coupling screws and taper-lock bolts with a torque wrench
set at 40 - 45 foot-pounds (54 - 61 Nm) .
e. Return the unit to normal service.
f. After each additional 2,000 hours of operation (or every year) recheck all coupling screws to
maintain the same torque value.