MADE IN GERMANY
www.hne.ag
OPEN
Relieve the system always completely from residual
pressure before opening the container lid. Even after
complete discharge of the extinguisher, new pressure
can occur due rising temperature.
Venting the system:
2.
Turn the upper knob into open
position ( ) for venting.
1.
Make sure that the valve of the
compressed air cylinder is closed.
3.
Press and hold the trigger of the jet
gun until no more hissing is heard.
4.
Place the device on a level surface
and remove the pressure bottle (see
next page). Then unscrew the lid.
Closing the lid:
A thin layer of silicon grease on thread and
sealing surface increases lifetime and
facilitates opening. Screw the lid tightly and
turn the vent valve into closed position ( ).
Tightening by hand is sufficient. Do not use tools.
Silicon
grease
CLOSED
HiPRESS 50 - COLD METAL
The container requires a total filling of exactly 50.0 liters of
"HNE-Cold Metal". The specialized extinguishing media comes
ready for use. Never dilute or mix it with any other fluids.
Amount and mixing ratio: