HBU Series Braking Unit
25
Table 4.1 Operation panel of HBU-3HA/4HA/5HA
*Except HBU-3HA/4HA/5HA series dynamic braking units, there
is no operation panel for other HBU series dynamic braking units in this
manual.
4.2 Status Indication
There are five indicator lights for Status indication of
HBU-3HA/4HA/5HA, each has its implication.
Table 4.1
Definition of indicator light
Indicator
Function
Implication
PWR
Power
supply
indication
light is on after power on
SET
Parameter
status
indication
When light is on, parameters is
checkable, can check out rated voltage,
maximum current, operation voltage,
temperature for heat sinking, malfunction
records, and software version. When the
light flash, rated voltage & operation
voltage can be set.
Содержание HBU Series
Страница 1: ...HBU Series Braking Unit User s Manual HNC Electric Limited ...
Страница 13: ...HBU Series Braking Unit 12 2 4 Product installation dimension HBU 1L dimension ...
Страница 14: ...HBU Series Braking Unit 13 HBU 1SA 3SA dimension ...
Страница 15: ...HBU Series Braking Unit 14 HBU 3HA 4HA 5HA 6HA dimension ...