WEB-PLC Editor

25 (38)

7.2

Debugging

The current state of the variables and constants in the PLC can be checked directly in the
diagram view via the Live View function.

Fig. 12

Live view

Click button

Editor

to open the WEB-PLC editor and open tab

Diagram

(

1

).

To check the state of a configured PLC, click button

Start Live View

(

2

).

Current value of each output port is shown next to the port in blue (

3

).

Values are updated constantly.

Stop Live View before changing the diagram! If the PLC does not match the diagram, an
error occurs and the Live View is stopped.

SG-basic User Manual

4.01.0401.20001 1.1 en-US

Содержание IXXAT SG-basic

Страница 1: ...SG basic Extended Version USER MANUAL 4 01 0401 20001 1 1 en US ENGLISH...

Страница 2: ...ssible applications of the product and because of the many variables and requirements associated with any particular implementation HMS Networks cannot assume responsibility or liability for actual us...

Страница 3: ...5 Installation 10 5 1 System Requirements 10 5 2 Installing the Hardware 11 5 3 Reset the Device 13 6 Configuration 14 6 1 Accessing the Device 14 6 2 Accessing the Embedded WEB PLC 15 6 3 Activating...

Страница 4: ...PLC LED B 31 10 Technical Data 32 11 Support Return Hardware 33 11 1 Support 33 11 2 Return Hardware 33 12 Decommissioning and Disposal 33 A Regulatory Compliance 35 A 1 EMC Compliance CE 35 A 2 Disp...

Страница 5: ...All configurations done via the WEB PLC are described in detail in the integrated WEB PLC online help available via the web interface 1 2 Related Documents Document Author OpenVPN documentation http...

Страница 6: ...4 This is an external link URL www hms networks com Safety advice is structured as follows Cause of the hazard Consequences of not taking remediate action How to avoid the hazard Safety signs and sign...

Страница 7: ...y features HMS recommends to activate and use this security features as described in the following chapters 2 2 1 OpenVPN HMS recommends using encoding via OpenVPN if supported by all participants to...

Страница 8: ...ure for each user different access rights for the different device functions Make sure that each user only has the access rights that are required to perform the tasks of their role to minimize securi...

Страница 9: ...ing the firmware see Updating the Firmware p 16 2 2 8 Event Log The event log is cleared when the device is restarted and new events may overwrite older events once the ring buffer is completely fille...

Страница 10: ...Scope of Delivery 8 38 Quick Start Guide Micro SD card 1 x power connector 3 pin 1 x serial interface RS485 SG basic User Manual 4 01 0401 20001 1 1 en US...

Страница 11: ...scriber and Publisher IEC 60870 5 104 Client Server DNP3 Outstation Modbus TCP Client Slave Modbus RTU Master Slave OPC UA server MQTT publisher subscriber Kolibri for connection to the optional HMS H...

Страница 12: ...he following features are needed on the local computer for the device configuration Ethernet network interface and Ethernet connection to the device local or internet Java script capable web browser r...

Страница 13: ...Make sure that the Micro SD card is inserted 2 Power connector FE Functional earth 3 Power connector GND Ground 4 Power connector VCC 24 V DC 5 Serial interfaces RS485 pin B B Z 6 Serial interface RS4...

Страница 14: ...ted to functional earth Make sure that the device is connected to the power supply see Cabling p 12 5 2 3 Cabling Damaged device caused by reverse polarity or wrong power supply Make sure that power i...

Страница 15: ...button 1 While holding the Reset button 1 connect the device to power supply Hold the Reset button until all LEDs are flashing twice This can take up to 20 seconds When the reset is acknowledged all L...

Страница 16: ...with the MAC on the label of the device To rescan the network click button Scan 2 Select desired device in drop down list 1 Current IP configuration of the device is displayed 4 By default the device...

Страница 17: ...ial components such as the cellular modem or OpenVPN To configure the settings click icon Settings Event Log is opened which displays all events information messages warnings and errors generated by t...

Страница 18: ...or more information about updating the firmware see WEB PLC Online Help Update Damaged device if ongoing firmware update is stopped or cancelled Do not disconnect the power supply reset the device or...

Страница 19: ...the device IP settings using the latest Ixxat IP configurator downloadable from www ixxat com Use an up to date browser version Firefox Chrome Chromium MS Edge or Apple Safari Enter IP address of the...

Страница 20: ...is allowed or not can be configured in Settings Services Update If the firmware on the device is older than 19 3 32 update first to firmware version 19 3 32 and then to newer versions Update to versi...

Страница 21: ...tree select General User Management Fig 7 User management To change the password of user ixxat Select ixxat in the user list 1 click button Edit 3 Window Edit user is opened Define a new password If d...

Страница 22: ...ord Define the access rights for the different device functions Observe the distinction between the right to modify data or to only view data Click button OK Window Add user is closed New user is ente...

Страница 23: ...n importing this package Note that if the IP settings are contained in the export 3 the IP address of a device may be changed when importing this package To secure the configuration file with a passwo...

Страница 24: ...C editor All settings that are contained in the imported configuration overwrite the respective existing settings on the device Existing configurations of other protocols and settings that are not con...

Страница 25: ...on Editor Tab Diagram is opened To add a timer click Add unit and select Timing Timer Timer unit is added to the diagram To add a counter click Add unit and select Numerical Counter Counter unit is ad...

Страница 26: ...edge of the clock signal triggers the counter unit to increment its value Fig 11 Enabled timer Enabling the port by double clicking on the port is called negation Negation is performed logically value...

Страница 27: ...itor to open the WEB PLC editor and open tab Diagram 1 To check the state of a configured PLC click button Start Live View 2 Current value of each output port is shown next to the port in blue 3 Value...

Страница 28: ...sages via MQTT a broker must be configured MQTT is an open and unprotected protocol and third parties can read the transmitted messages if a public broker is used HMS recommends to use TLS to prevent...

Страница 29: ...ecv Msg 0 puts out a high signal 1 on its output port when the first configured message is received For more information about the MQTT configuration and security options when publishing to the cloud...

Страница 30: ...WEB PLC Online Help Settings Event Log via button Click icon Settings Event Log is opened Event messages consisting of message text timestamp and event type are shown Timestamps are displayed in the...

Страница 31: ...possible command is opened Fig 13 Diagnostics console Select the tab of the desired command Info Shows information about the available network the routing table or the DNS configuration Ping Transmit...

Страница 32: ...ment to the data logging list To add an element click button Add Window Edit Element is opened Configure the element settings Element Settings Name Description of the corresponding database entry Elem...

Страница 33: ...g 0 5 Hz Connecting to HMS Hub in progress On Connection to HMS Hub is established 9 3 PLC LED B The PLC LED indicates the status of the PLC LED Description Off No program loaded PLC not running Slowl...

Страница 34: ...r Name Password Server Facet Security Policies None Basic128Rsa15 Basic256Sha256 Protocol and encoding UA TCP UA SC UA Binary protocol and encoding Data change notification Embedded DataChange Subscri...

Страница 35: ...ty claims and repair Print out the Product Return Number PRN resp RMA Pack product in a physically and ESD safe way use original packaging if possible Enclose PRN number Observe further notes on www i...

Страница 36: ...This page intentionally left blank...

Страница 37: ...arately from household waste When this product reaches its end of life contact local authorities to learn about disposal and recycling options or simply drop it off at your local HMS office or return...

Страница 38: ...ove the devices are certified with the following marking Intended Use SG gateways are used to connect MODBUS devices energy communication systems and industrial equipment with each other and to SCADA...

Страница 39: ...ne inversion de polarit ou un mauvais type d alimentation Lors de la connexion v rifiez que la polarit est correcte et que l alimentation est du type recommand Les quipements doivent tre mis la masse...

Страница 40: ...last page 2021 HMS Industrial Networks Box 4126 300 04 Halmstad Sweden info hms se 4 01 0401 20001 1 1 en US 2021 05 27 22590...

Отзывы: