Common errors
Error code
Reason
How to solve
(OR
E00/E07)
1. safety key off
1. put on safety key
2. magnetron not fixed well
2. fix magnetron to right position
E01/E13
1. signal wire not well connected
1. re-connect signal wire
2. signal wire broken
2. change new signal wire
3. signal wire broken
3. change new computer
4. pcb broken
4. change new pcb
E02
1. motor wire not well conected or open
1. re-connect motor wire or change new
motor
2. pcb broken
2. change new pcb
3. imput voltage too low
3. stop using, ask electrician to check
E03
1. speed signal wire not well connected
1. re-connect speed signal wire or change
new sensor wire
2. pcb broken
2. change new pcb
E05
1. over
–
loaded
1. turn off and re-start machine
2. driving position hinder
2. adjust driving position or add oil
3. motor short circuit
3. change new motor
4. pcb bumt
4. change new pcb
E06
1. motor wire not well connected
1. re-connect motor wire
2. motor open circuit
2. change new motor
3. motor idling
3. re-assemble to test
E08
1. storage IC not well inserted
1. re-insert IC, pay attention to pins
2. storage IC broken or pcb broken
2. change new IC or change new pcb
E09
1. machine stand or not put evenly on
1. Put evenly on floor
2. pcb broken
2. change ew pcb
E10
1. pcb torque too big
1. adjust torque to right position
2. motor short circuit
2. change new motor
3. transportation rollers are not working
smoothly
3. adjust belt position
E11
1. input voltage too big
1. stop using, ask electrician to check
E14
1. input voltage too low
1. stop using, ask electrician to check