14 (44)
Notes:
•
Mode 1 will scan for units in mode 4. When a unit in mode 4 is detected, the scanning unit
will configure itself as a Bluetooth PANU client, send a connection configuration to the
detected unit, and restart. The detected unit will also restart and attempt to connect to the
first unit as a PANU client.
•
Modes 5, 6, 7 and 8 will scan for units in mode 4. The detected units will be reconfigured as
clients and the scanning unit will restart as an access point. The clients will then restart and
connect to the access point.
•
Modes 7 and 8 will additionally apply PROFINET optimization to all the units. PROFINET
messages will then have priority over TCP/IP frames.
•
Mode 11 locks the unit in PROFIsafe mode where the configuration cannot be changed
without physical access. To cancel this mode the unit must be restored to factory defaults
by pressing and holding the MODE button.
•
Modes 10 and 11 will be added to the configuration without changing any other settings.
•
Modes 1 and 9 will listen for 40 seconds or until a configuration is established.
•
Modes 4 will listen for 120 seconds or until receiving a configuration.
•
Modes 5, 6, 7 and 8 will time out after 120 seconds.
Anybus
®
Wireless Bridge II
™
User Manual
SCM-1202-032 1.10 en-US
Содержание Anybus Wireless Bridge II
Страница 1: ...Anybus Wireless Bridge II USER MANUAL SCM 1202 032 1 10 en US ENGLISH...
Страница 4: ...This page intentionally left blank...
Страница 30: ...This page intentionally left blank...