Appendix B: Wireless Technology Basics

40 (44)

B

Wireless Technology Basics

Wireless technology is based on the propagation and reception of electromagnetic waves. These

waves respond in different ways in terms of propagation, dispersion, diffraction and reflection

depending on their frequency and the medium in which they are travelling.
To enable communication there should optimally be an unobstructed line of sight between the

antennas of the devices. However, the so called

Fresnel Zones

should also be kept clear from

obstacles, as radio waves reflected from objects within these zones may reach the receiver out

of phase, reducing the strength of the original signal (also known as phase cancelling).
Fresnel zones can be thought of as ellipsoid three-dimensional shapes between two wireless

devices. The size and shape of the zones depend on the distance between the devices and on the

signal wave length. As a rule of thumb, at least 60 % of the first (innermost) Fresnel zone must

be free of obstacles to maintain good reception.

Fig. 30

Fresnel zones

Area to keep clear of obstacles (first Fresnel zone)

Distance (d)

Fresnel zone radius (r)

2.4 GHz (WLAN or Bluetooth)

5 GHz (WLAN)

100 m

1.7 m

1.2 m

200 m

2.5 m

1.7 m

300 m

3.0 m

2.1 m

400 m

3.5 m

2.4 m

The wireless signal may be adequate even if there are obstacles within the Fresnel zones, as it

always depends on the number and size of the obstacles and where they are located. This is

especially true indoors, where reflections on metal objects may actually help the propagation of

radio waves. To reduce interference and phase cancelling, the transmission power of the unit

may in some cases have to be reduced to limit the range.

It is therefore recommended to use a wireless signal analysis tool for determining the optimal

placement and configuration of a wireless device.

Anybus

®

Wireless Bolt Serial

User Manual

SCM-1202-143 1.10 en-US

Содержание Anybus Wireless Bolt Series

Страница 1: ...Anybus Wireless Bolt Serial USER MANUAL SCM 1202 143 1 10 en US ENGLISH...

Страница 2: ...plications of the product and because of the many variables and requirements associated with any particular implementation HMS Networks cannot assume responsibility or liability for actual use based o...

Страница 3: ...ation 6 4 1 Mechanical Installation 6 4 2 Connector 7 4 3 Cabling 8 4 4 Digital Input 8 4 5 RESET Button 9 5 Configuration 10 5 1 Web Interface 11 5 2 Use Cases 29 5 3 Set Up a Wireless Infrastructure...

Страница 4: ...This page intentionally left blank...

Страница 5: ...gram code and script examples Cross reference within this document Document Conventions p 3 External link URL www hms networks com WARNING Instruction that must be followed to avoid a risk of death or...

Страница 6: ...immunity requirements For domestic environments the functional earth must be used if a shielded Ethernet cable is used in order to meet emission requirements This equipment contains parts that can be...

Страница 7: ...tance of 50 cm between the devices should also be observed to avoid interference See also Wireless Technology Basics p 40 3 2 When to Use Bluetooth and WLAN Use Bluetooth when The wireless link has an...

Страница 8: ...sh equivalent to Ra 3 2 or finer and cleaned and free from oils and greases Tightening torque 5 Nm 10 Make sure that the sealing ring is correctly placed in the circular groove in the top part of the...

Страница 9: ...gital input 9 30 V 4 DI_GND Digital input ground 5 ETN_RD Ethernet receive white orange 6 ETN_RD Ethernet receive orange 7 ETN_TD Ethernet transmit green 8 ETN_TD Ethernet transmit white green 9 RS485...

Страница 10: ...orange white green and green white wires The shield and the other wires are not used 3 Strip off about 7 mm inch of the isolation on each wire 4 Push the pin spring release next to each socket on the...

Страница 11: ...e accessed the unit can be reset by starting in Recovery Mode and reinstalling the firmware using Anybus Firmware Manager II which can be downloaded from www anybus com support To enter Recovery Mode...

Страница 12: ...ss of the Bolt Serial The default address is 192 168 0 99 The computer accessing the web interface must be in the same IP subnet as the Bolt Serial Fig 5 Web interface Advanced configuration can be ca...

Страница 13: ...e different parameters are explained in the descriptions of each settings page in this manual The Help page describes AT commands that can be used for advanced configuration Save and Reboot This butto...

Страница 14: ...ettings to factory defaults 4 Client Wait for automatic configuration Listens for 120 seconds or until receiving a configuration Configure units in mode 4 as clients When mode 4 is used with mode 1 5...

Страница 15: ...d wirelessly via a PC connected to the Wireless Bolt or Bridge Access Point After factory reset Wireless Bolt will by default start in Easy Config Mode 4 if there is no Ethernet connection When connec...

Страница 16: ...ctionality DHCP Relay Enabled The unit can receive a DHCP request on one interface and resend it to a DHCP server located on one of the other interfaces Only a single DHCP server can be active for all...

Страница 17: ...th Start Address Y The internal DHCP server will assign up to 7 IP addresses starting from X X X Y where X is taken from the current static IP address setting and Y is the value in Start Address Alrea...

Страница 18: ...d at a time Scan for Networks Click to scan the selected frequency band s for discoverable WLAN networks Select a network from the dropdown menu to connect to it Connect to SSID To connect manually to...

Страница 19: ...figuration The network cannot enforce a 1 to 1 mapping of IP to MAC addresses and must allow propagation of broadcasted ARP messages over the wireless segment in order to route traffic to the bridged...

Страница 20: ...e enabled A new scan will be performed every hour to update the regulatory domain If no country information or conflicting information is detected the unit will revert to World Mode The unit must then...

Страница 21: ...between 8 and 63 characters All characters in the ASCII printable range 32 126 are allowed except double quote comma and backslash Hexadecimal passwords must start with 0x and be exactly 64 characters...

Страница 22: ...Bluetooth devices If left blank the unit will use a default name including the last 6 characters of the MAC ID Connectable Enable to make the unit accept connections initiated by other Bluetooth devic...

Страница 23: ...completed Connect To Used when connecting manually to a NAP or PANU device Connection Scheme Choose whether to select a Bluetooth device by MAC address default or Name when connecting manually Connec...

Страница 24: ...ward IP data will be bridged over Bluetooth This mode must be used when connecting to an Android device over Bluetooth The network must have an active DHCP server List Nearby Devices Scans the network...

Страница 25: ...etting Up Serial Communication Fig 15 Example Serial Settings TCP Mode Server with Modbus TCP to Modbus RTU Gateway function enabled Fig 16 Example Serial Settings TCP Mode Client Anybus Wireless Bolt...

Страница 26: ...on is selected the communication is optimized to keep all Modbus packets together in one frame This mode should only be enabled when communicating with MODBUS RTU devices TCP Mode Select a TCP Mode fr...

Страница 27: ...to point link or a point to multipoint link A message sent from a master to a Bolt Serial is forwarded to all the connected slaves The slave response sent to the Bolt Serial is forwarded to the master...

Страница 28: ...Send to send it to the unit Fig 18 Firmware update in progress Both progress bars will turn green when the firmware update has been completed The unit will then reboot automatically Fig 19 Firmware u...

Страница 29: ...web interface to read out parameters in text format and for batch configuration using command scripts Enter or paste the commands into the text box then click on Send The result codes will be display...

Страница 30: ...he unit is strongly recommended Settings Backup Create Settings Backup Click on Generate to save the current configuration to a file on your computer Restore Settings Click on Choose file and select a...

Страница 31: ...s of Bolt Serial which creates a wireless bridge for the serial communication 5 2 2 Installing Multiple Bolt Serial Fig 23 When installing more than one Bolt Serial in the bridge configure the Bolt Se...

Страница 32: ...etwork configure the Bolt Serial connected to the Master device as the Wireless Access point AP Slave as a Wireless Client In the Bolt Serial access point web interface Serial Settings tab select the...

Страница 33: ...bus TCP Client as the Access Point AP or Network Access Point NAP The Modbus RTU Slave connected to Bolt Serial B with IP address 192 168 0 100 The other Modbus RTU Slaves are connected to Bolt Serial...

Страница 34: ...cess to the devices over the network Procedure To set up TCP IP communication 1 Establish IP connectivity between the devices using either WLAN or Bluetooth PAN profile 2 Do one of the following Open...

Страница 35: ...Config 5 3 1 Connecting the Devices Fig 27 Serial bridge example 1 Connect Client unit 1 to a Serial device 2 Connect Access Point unit 2 to the master device 3 Connect Access Point unit 2 to your PC...

Страница 36: ...ll be assigned the first free IP address in the same Ethernet subnet as Access Point unit 2 The default address to the first Client unit is 192 168 0 100 If no connection is established during Easy Co...

Страница 37: ...s Optimization When Modbus Optimization is selected the communication is optimized to keep all Modbus packets together in one frame This mode should only be enabled when communicating with Modbus RTU...

Страница 38: ...isabled DHCP Interfaces All Default WLAN Settings Operating Mode Client Channel Bands 2 4 GHz 5 GHz Authentication Mode WPA WPA2 PSK Channel Auto Bridge Mode Layer 3 IP forward Default Bluetooth Setti...

Страница 39: ...ach axes Velocity 1 oct min Mode in operation Frequency 5 500 Hz Displacement 3 5 mm Acceleration 2g Shock test according to IEC 60068 2 27 2008 and with extra severities Wave shape half sine Number o...

Страница 40: ...This page intentionally left blank...

Страница 41: ...nt devices in this product A is TX RX or D and B is TX RX or D A 1 RS485 Typical Connection The resistors on the Bolt Serial side are termination resistors which form an active termination of the RS48...

Страница 42: ...n the distance between the devices and on the signal wave length As a rule of thumb at least 60 of the first innermost Fresnel zone must be free of obstacles to maintain good reception Fig 30 Fresnel...

Страница 43: ...same distance C 1 Azimuth Horizontal View This diagram shows the horizontal antenna pattern when looking at the Bolt from above i e looking at the top logo from above Diagram analysis the diagram dis...

Страница 44: ...ed by the yellow box below the Bolt Diagram analysis The vertical antenna gain is fairly omnidirectional for both frequencies It is also clear to see that the metal cabinet where the Bolt is mounted w...

Страница 45: ...eases Note the huge difference between using a backshield to focus the radio energy and not using a backshield Using a backshield can greatly increase radio coverage if used correctly The diagram cove...

Страница 46: ...last page 2021 HMS Industrial Networks Box 4126 300 04 Halmstad Sweden info hms se SCM 1202 143 1 10 en US 2021 06 03 22664...

Отзывы: