34 (44)
5.3.2
Activate Easy Config
1. Navigate to the web interface of
Access Point unit 2
.
The default address to
Access Point unit 2
is
192.168.0.99
.
2. Activate one of the following Easy Config Modes:
–
Easy Config Mode 1
for Bluetooth PANU-PANU. Used for setting up point-to-point
communication.
–
Easy Config Mode 5
for WLAN
–
Easy Config Mode 6
for Bluetooth
3. Connect
Client unit 1
to power.
→
Client unit 1
starts up in
Easy Config Mode 4
and is open for automatic configuration during
120 seconds.
→
Access Point unit 2
will discover and configure
Client unit 1
as a
Client
and configure itself as
an
Access Point
.
→
Client unit 1
will be assigned the first free IP address in the same Ethernet subnet as
Access
Point unit 2
.
The default address to the first
Client unit
is
192.168.0.100
.
→ If no connection is established during Easy Config Mode:
–
Ensure that
Client unit 1
is disconnected from Ethernet.
–
Disconnect
Client unit 1
from power and repeat Activate Easy Config step 5 and 6.
5.3.3
Adding More Bolt Serial Clients
When using
Easy Config Mode 1
, continue with Serial Configuration.
When using
Easy Config Mode 5
or
Easy Config Mode 6
, up to 6 additional Bolt Serial Clients can
be added to the Serial bridge.
1. To add more
Client units
, repeat Connecting the Devices step 1 and the Activate Easy Config
steps.
→ Each new
Client unit
will be assigned the next free IP address in the current Ethernet subnet.
Anybus
®
Wireless Bolt Serial
™
User Manual
SCM-1202-143 1.10 en-US