Design Guide
Revision 1.12
1998-08-12
HMS F
IELDBUS
S
YSTEMS
AB
Page 15 (35)
•
read only (AB-DT
⇒
application)
This register contains the software version in the AB-DT module.
5 Fieldbus type (3F7h)
•
read only (AB-DT
⇒
application)
This register indicates the fieldbus system which the AB-DT supports.
Code
Function
Fieldbus system
00h
PDP
Profibus-DP
08h
IBS
InterBus-S
10h
LON
Lonworks
18h
DEV
DeviceNet
20h
COP
CAN open
30h
FIP
FIP IO
38h
MBP
Modbus Plus
48h
RIO
Remote IO
Table 3. Supported fieldbus system
The list of supported fieldbus systems is continuously updated.
6 Input length (3F8h - 3F9h)
•
read / write during initialisation (application
⇐⇒
AB-DT)
•
read only (AB-DT
⇒
application)
The word access is done in Motorola mode. The even byte consists of the upper 8 significant bits (bit 8-15;
bit 10-15 are always 0), the odd byte consists the lower significant bits (bit 0-7).
Any value set by the application that exceeds the maximum value of the fieldbus in use will be adjusted to
maximum number of inputs or outputs by the AnyBus module.
7 Output length (3FAh - 3FBh)
•
read / write during initialisation (application
⇐⇒
AB-DT)
•
read only (AB-DT
⇒
application)
The word access is done in Motorola mode. The even byte consists of the upper 8 significant bits (bit 8-15;
bit 10-15 are always 0), the odd byte consists the lower significant bits (bit 0-7).
Any value set by the application that exceeds the maximum value of the fieldbus in use will be adjusted to
maximum number of inputs or outputs by the AnyBus module.
3F8h
HIGH BYTE
3F9h
LOW BYTE
3FAh
HIGH BYTE
3FBh
LOW BYTE
Table 4. Motorola mode representation