Appendix E: Implementation Guidelines
44 (48)
E
Implementation Guidelines
E.1
General
This appendix provides an example of a possible implementation for the Anybus CompactCom
B40 Modbus Serial.
There are many different processors with different functionality available on the market today.
The implementation in this appendix is to be regarded as an example that is designed for one
single type of processor. Other hardware interfaces may require adjustments for timing, different
functionality etc. It is important to fully understand the interface to take correct design decisions
in order to obtain a stable and reliable design.
E.2
Example
The example in the figure below shows an implementation with Modbus Serial communication.
Host Application
CPU (3.3V)
3V3
3V3
3V3
OM0
OM1
OM2
Tx/OM3
Rx
IRQ
RESET
MI0/SYNC
MI1
MD
Rx
Tx
GPIO5
GPIO6
GPIO7
GPIO8
GPIO10
INPUT2_0
INPUT2_1
INPUT2_2
INPUT2_3
INPUT2_4
INPUT2_5
INPUT2_6
INPUT2_7
3V3
3V3
INPUT1_0
INPUT1_1
INPUT1_2
INPUT1_3
INPUT1_4
INPUT1_5
INPUT1_6
INPUT1_7
Modbus address,
either strapped
or from switch
Number of stop bits,
parity and baud rate
strapped
or from switch
Fig. 25
Anybus
®
CompactCom
™
B40 Modbus Serial User Manual
SCM-1202-130 1.1 en-US