25 (48)
4.2.4
Ethernet Based Networks (Copper)
The industrial networks, that use Ethernet for communication, share the same hardware design.
However, the firmware downloaded to the brick is different depending on network. Physically
they use the same set of pins in a similar way. At the moment Anybus CompactCom B40 Modbus
Serial is available for the following Ethernet based networks: EtherNet/IP and PROFINET IRT.
The brick supports dual network ports, signal group A should be connected to the left port (port
1) and signal group B to the right port (port 2) on the connector board, looking at the front, see
Connector Board for Copper Based Ethernet, p. 35
Signal Group
Signal Name
Type
Pin
Description
B
B_1P
I/O
3
First pair, positive signal
B_1CEN
Power
4
Center tap voltage for first pair
B_1N
I/O
5
First pair, negative signal
B_2P
I/O
7
Second pair, positive signal
B_2CEN
Power
8
Center tap voltage for second pair
B_2N
I/O
9
Second pair, negative signal
B_3P
I/O
11
Third pair, positive signal. Used for Gigabit Ethernet.
B_3CEN
Power
12
Center tap voltage for third pair. Used for Gigabit
Ethernet.
B_3N
I/O
13
Third pair, negative signal. Used for Gigabit Ethernet.
B_4P
I/O
15
Fourth pair, positive signal. Used for Gigabit Ethernet.
B_4CEN
Power
16
Center tap voltage for fourth pair. Used for Gigabit
Ethernet.
B_4N
I/O
17
Forth pair, negative signal. Used for Gigabit Ethernet.
A
A_1P
I/O
29
First pair, positive signal
A_1CEN
Power
30
Center tap voltage for first pair
A_1N
I/O
31
First pair, negative signal
A_2P
I/O
33
Second pair, positive signal
A_2CEN
Power
34
Center tap voltage for second pair
A_2N
I/O
35
Second pair, negative signal
A_3P
I/O
37
Third pair, positive signal. Used for Gigabit Ethernet.
A_3CEN
Power
38
Center tap voltage for third pair. Used for Gigabit
Ethernet.
A_3N
I/O
39
Third pair, negative signal. Used for Gigabit Ethernet.
A_4P
I/O
41
Fourth pair, positive signal. Used for Gigabit Ethernet.
A_4CEN
Power
42
Center tap voltage for fourth pair. Used for Gigabit
Ethernet.
A_4N
I/O
43
Forth pair, negative signal. Used for Gigabit Ethernet.
4.2.5
Ethernet Fiber Optic Networks
Ethernet fiber optic networks use more or less the same pins as copper based Ethernet networks.
The brick supports PROFINET fiber optic network (PROFINET IRT).
The brick supports dual network ports, signal group A is be connected to the left port (port 1)
and signal group B to the right port (port 2)on the connector board, looking at the front, see
Fiber Optic Conenctor LÄNK!!.
If the Anybus CompactCom B40 connector board is not to be used, please study the design
requirements for the Rx and SD channels, see
Rx Channel Design Requirements, p. 26
and
Channel Design Requirements, p. 27
. Furthermore, fiber optic connectors without metal are
preferred in order to minimize EMC disturbance.
Anybus
®
CompactCom
™
B40 Modbus Serial User Manual
SCM-1202-130 1.1 en-US