Appendix A: Technical Specification
32 (48)
A.3.1
Operating Conditions
Symbol
Parameter
Pin
Types
Conditions
Min.
Typ.
Max.
Unit
3V3
Supply Voltage (DC)
PWR
-
3.15
3.30
3.45
V
Ripple (AC)
-
-
± 100
mV
GND
Ground reference
0.00
0.00
0.00
V
I
IN
Current consumption
(also including network
interfaces and network
status LEDs)
Class A
-
-
250
mA
Class B
-
-
500
mA
Class C
-
-
1000
mA
V
IH
Input High Voltage
I, BI
-
2.0
-
3.45
V
V
IL
Input Low Voltage
-0.3
-
0.8
V
I
OH
Current, Output High
O, BI
-
-8.0
-
8.0
mA
I
OL
Current, Output Low
V
OH
Output High Voltage
I
OH
= -4mA
2.4
-
-
V
V
OL
Output Low Voltage
I
OL
= 4mA
-
-
0.4
V
I
OH
(NW_
LEDx)
Output Current ,
network LEDs
O
20
mA
I= Input, CMOS (3.3V)
O= Output, CMOS (3.3V)
BI= Bidirectional, Tristate
PWR= Power supply inputs
A.4
Regulatory Compliance
EMC Compliance (CE)
Since the Anybus CompactCom is considered a component for embedded applications it cannot
be CE-marked as an end product.
However the Anybus CompactCom 40 family is pre-compliance tested in a typical installation
providing that all modules are conforming to the EMC directive in this installation.
The EMC pre-testing has been conducted according to the following standards:
Emission: EN61000-6-4
EN55016-2-3 Radiated emission
EN55022 Conducted emission
Immunity: EN61000-6-2
EN61000-4-2 Electrostatic discharge
EN61000-4-3 Radiated immunity
EN61000-4-4 Fast transients/burst
EN61000-4-5 Surge immunity
EN61000-4-6 Conducted immunity
Since all Anybus CompactCom B40 Modbus Serial modules have been evaluated according to the
EMC directive through above standards, this serves as a base for our customers when certifying
Anybus CompactCom B40 Modbus Serial based products.
Anybus
®
CompactCom
™
B40 Modbus Serial User Manual