14 (18)
4.4
Factory Restore
Any one of these actions will restore the factory default settings:
•
Clicking on
Factory Restore
on the
System Settings
page
•
Executing
Easy Config Mode 2
•
Issuing the AT command
AT&F
and then restarting the unit
•
Holding
MODE
pressed for >10 seconds and then releasing it
•
Applying voltage to the digital input for >10 seconds
Default Network Settings
IP Assignment
Static
IP Address
192.168.0.99
Subnet Mask
255.255.255.0
Default Gateway
192.168.0.99
Internal DHCP Server
Disabled
DHCP Interfaces
All
Default WLAN Settings
Operating Mode
Client
Channel Bands
2.4 GHz & 5 GHz
Authentication Mode
WPA/WPA2–PSK
Channel
Auto
Bridge Mode
Layer 3 IP forward
MIMO
AWB3000: Enabled
AWB3010: Disabled
Default Bluetooth Settings
Operating Mode
PANU (Client)
Local Name
[generated from MAC address]
Connectable
No
Discoverable
No
Security Mode
Just works
Bluetooth LE
Operating Mode: Disabled
Connectable: No
Discoverable: No
Anybus
®
Wireless Bridge II
™
Startup Guide
SP2167 2.1 en-US