background image

Configuration

11 (18)

4

Configuration

Anybus Wireless Bridge II is normally configured via the web interface or using
one of the pre-configured

Easy Config

modes.

Advanced configuration can be carried out by issuing AT commands via the web
interface or over a Telnet or RAW TCP connection to port 8080.

4.1

Web Interface

The web interface is accessed by pointing a web browser to the IP address of
the unit. The default address is

192.168.0.99

.

The configuration settings are described in detail in the User Manual.

Anybus

®

Wireless Bridge II

Startup Guide

SP2167 2.1 en-US

Содержание Anybus AWB3000

Страница 1: ...Anybus Wireless Bridge II STARTUP GUIDE SP2167 2 1 en US ENGLISH ...

Страница 2: ...le applications of the product and because of the many variables and requirements associated with any particular implementation HMS Networks cannot assume responsibility or liability for actual use based on the data examples or illustrations included in this document nor for any damages incurred during installation of the product Those responsible for the use of the product must acquire sufficient...

Страница 3: ...truction that must be followed to avoid a risk of death or serious injury Caution Instruction that must be followed to avoid a risk of personal injury Instruction that must be followed to avoid a risk of reduced functionality and or damage to the equipment or to avoid a network security risk Additional information which may facilitate installation and or operation 1 2 Trademarks Anybus is a regist...

Страница 4: ...unctional earth connection to comply with immunity requirements For domestic environments the functional earth must be used if a shielded Ethernet cable is used in order to meet emission requirements This equipment contains parts that can be damaged by electrostatic discharge ESD Use ESD prevention measures to avoid damage 2 2 External Antenna Restrictions For models with external antenna only use...

Страница 5: ...t may be impaired 2 4 Type Identification The type name consists of a type prefix followed by two designators for interface configuration and functionality Prefix AWB3 Anybus Wireless Bridge II Interface configuration A B Internal antenna Dual M12 External antenna Dual M12 RP SMA Functionality A B Ethernet with digital input Ethernet w o digital input Example AWB3AA Anybus Wireless Bridge II with ...

Страница 6: ...l A minimum distance of 50 cm between the devices should also be observed to avoid interference For models with internal antenna the characteristics of the antenna should be considered when choosing the placement and orientation of the unit See the User Manual for more information about the antenna characteristics for this equipment Make sure that you have all the necessary information about the c...

Страница 7: ...s applied to the digital input for more that 10 seconds the unit will be reset to factory defaults Signal wiring for the digital input must be carried in the same cable as power and functional earth if wiring length exceeds 3 meters See www anybus com support for more information about the digital input LAN Connector D coded female M12 Pin Function Color coding T568B 1 Transmit Orange White 2 Rece...

Страница 8: ...blinking Client Scanning for access points Purple Client Connecting to a detected access point Red Unrecoverable error LAN Off No Ethernet connection Yellow Ethernet link present Yellow flickering Ethernet data activity when connected BT Off Bluetooth disabled or no power Blue blinking NAP No clients awaiting connections Blue NAP Connected to at least one PANU client PANU Connected to NAP Blue fli...

Страница 9: ...RSSI Link Quality 25 A B RSSI Link Quality 25 50 A B C RSSI Link Quality 50 75 A B C D RSSI Link Quality 75 These LEDs are also used when selecting an Easy Config mode and to indicate update status in Recovery Mode See Easy Config p 12 and Recovery Mode LED Indications p 10 Anybus Wireless Bridge II Startup Guide SP2167 2 1 en US ...

Страница 10: ...ybus Firmware Manager II which can be downloaded from www anybus com support To enter Recovery Mode press and hold RESET during startup Firmware updates should normally be carried out through the web interface Recovery Mode should only be used if the unit is unresponsive and the web interface cannot be accessed Recovery Mode LED Indications In Recovery Mode the Status LEDs will indicate firmware u...

Страница 11: ... can be carried out by issuing AT commands via the web interface or over a Telnet or RAW TCP connection to port 8080 4 1 Web Interface The web interface is accessed by pointing a web browser to the IP address of the unit The default address is 192 168 0 99 The configuration settings are described in detail in the User Manual Anybus Wireless Bridge II Startup Guide SP2167 2 1 en US ...

Страница 12: ...PANU 2 B Reset configuration to factory defaults 3 A B Reset IP settings to factory defaults 4 C Client Wait for automatic configuration 5 A C WLAN AP Configure units in mode 4 as clients Restart as access point and connect clients 6 B C Bluetooth NAP 7 A B C WLAN AP Configure units in mode 4 as clients Restart as access point and connect clients Apply PROFINET optimization to all units 8 D Blueto...

Страница 13: ...ecommended to use the following minimum I O data cycle times for PROFINET and EtherNet IP networks Wireless link Point to Point with Bluetooth PANU PANU or Wi Fi Access Point to Station 32 ms Wireless link with Access Point and up to 4 wireless clients stations Bluetooth or Wi Fi 64 ms Anybus Wireless Bridge II Startup Guide SP2167 2 1 en US ...

Страница 14: ...nt Static IP Address 192 168 0 99 Subnet Mask 255 255 255 0 Default Gateway 192 168 0 99 Internal DHCP Server Disabled DHCP Interfaces All Default WLAN Settings Operating Mode Client Channel Bands 2 4 GHz 5 GHz Authentication Mode WPA WPA2 PSK Channel Auto Bridge Mode Layer 3 IP forward MIMO AWB3000 Enabled AWB3010 Disabled Default Bluetooth Settings Operating Mode PANU Client Local Name generated...

Страница 15: ... Storage temperature 40 to 85 C Humidity EN 600068 2 78 Damp heat 40 C 93 humidity for 4 days Vibration See datasheet Housing material Plastic see datasheet for details Protection class IP65 Mounting Screw mount or DIN rail using optional clip Power connector M12 male A coded Ethernet connector M12 female D coded Power supply 9 30 VDC 5 20 Cranking 12 V ISO 7637 2 2011 pulse 4 Reverse polarity pro...

Страница 16: ...Technical Data 16 18 5 2 Installation Drawing All measurements are in mm Anybus Wireless Bridge II Startup Guide SP2167 2 1 en US ...

Страница 17: ...This page intentionally left blank ...

Страница 18: ...last page 2020 HMS Industrial Networks Box 4126 300 04 Halmstad Sweden info hms se SP2167 2 1 en US 2020 11 30 20889 ...

Отзывы: