![HME ion BP COM6100 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/hme/ion-bp-com6100/ion-bp-com6100_operating-instructions-manual_2141391003.webp)
3
For ion IQ™ Audio Systems, register each COMMUNICATOR
®
as follows:
NOTE:
On the base station displays, “headset” refers to either Belt-Pacs or All-In-One Headsets.
•
•
•
•
On the ion IQ base station
STATUS
display, press the
Menu
button.
•
•
•
•
On the
MAIN MENU
display, press the
Register
button.
•
•
•
•
The
REGISTRATION
display indicates the number of belt-pacs already registered and how many more
can be registered.
If you would like to unregister some of your belt-pacs, turn OFF all the ones you want to unregister and
turn ON all the ones you want to remain registered, and then press the
Clear Inactive
button on the
REGISTRATION
display to unregister all the belt-pacs that are not turned on, and press the
Clear
Inactive
button on the
CLEAR INACTIVE REGISTRATIONS
display.
If you would like to unregister all of your belt-pacs, press the
Clear All
button on the
REGISTRATION
display and then press the
Clear All
button on the
CLEAR ALL REGISTRATIONS
display.
CAUTION:
When clearing all belt-pacs, the base station will shut down and re-start.
Begin registration:
•
•
•
•
To register belt-pacs, press the
Register Headset
button on the
REGISTRATION
display.
•
•
•
•
On the
TO REGISTER HEADSETS
display, follow the instructions in the box.
•
•
•
•
To register only one belt-pac, press the
Register Single
button.
To register more than one belt-pac, press the
Register Multi
button.
When each registration is successfully completed:
•
•
•
•
The ID number assigned to this belt-pac will be shown.
ID numbers are assigned sequentially as 0 thru 9, A, b, C, d and E.
•
•
•
•
The power light on the belt-pac will remain on steady green.
•
•
•
•
When you have finished registering belt-pacs, press the
Back
button to exit the registration mode. You can
repeat pressing the
Back
button until you return to the
MAIN MENU
or
STATUS
display.