HME ion BP COM6100 Скачать руководство пользователя страница 2

 

Belt-Pac Registration 

Each belt-pac must be registered for use with a specific base station.  The base station thereby recognizes all 
belt-pacs registered to it when their power is on, and will be able to tell the difference between them and other 
electronic equipment operating on similar frequencies.  A maximum of 15 belt-pacs can be registered.  If one 
is replaced, you must register the new one before you use it.  When a belt-pac is replaced, the old one 
remains in memory.  Register all active belt-pacs the same way, one at a time. 

NOTE:

  Belt-pacs must be within 6 feet (1.83 meters) of the base station while being registered.

 

 

 
 
 
 
 
 

 
 
 
 
 

 

For Wireless IQ

 Audio Systems, register each COMMUNICATOR

®

 as follows: 

NOTE:

  If the maximum number of 15 is exceeded, an “

F

” for Full will appear on the Communicator ID display.  

You must clear all current registrations and re-register all active belt-pacs.  See Figure 4.  Open the base station 
and press the CLEAR ALL REGISTRATION button and the RESET button at the same time.  Continue holding 
the CLEAR ALL REGISTRATION button after releasing the RESET button, until “c” appears on the display.   

Begin registration: 

 

Be certain all belt-pacs to be registered are turned off and the base station power is on. Other belt-pacs 
can be on or off. 

 

Open the base station and locate the items shown in Figure 4. 

  If no belt-pacs are on, the status light will be blinking red.  If any belt-pacs are on, the status light will 

be on steady green. 

 

Press the START REGISTRATION button.  

  The Communicator ID display will show a small “o” for open, and the status light will be blinking green. 

 

Either

 press and hold the 

B

 button on the belt-pac while pressing and releasing the power button to turn 

the belt-pac on, and then release the 

B

 button, 

or

 press the power button and hold it for approximately 10 

seconds.  This will cause the belt-pac to enter the registration mode.  

  The status light in the base station will be blinking green and the Communicator ID display will 

continue to show a small “o” for open.  The belt-pac power light will be blinking amber. 

When the registration is successfully 
completed: 

 

The green status light in the base station will be 
on steady and the Communicator ID display will 
show the ID number assigned to this belt-pac.  
ID numbers are assigned sequentially as 0 thru 
9, A, b, C, d and E. 

 

The power light on the belt-pac will remain  
on steady green. 

If registration failed: 

 

A message in the headset will say “Headset #, Battery Low/Half/Full, Registration …”   
The power light will blink red and after a delay of up to 1.5 minutes you will hear “

Registration failed

.” 

 

Note the condition of the STATUS light in the base station.  Press the RESET button.  The STATUS light 
may blink and change colors.  When the STATUS light returns to its previous condition, press the START 
REGISTRATION button and repeat the registration procedure. 

If the registration fails again: 

In the USA call 

HME Customer Support

 at 

1-800-848-4468

.   

  

 

 

 

Outside the USA, call your local HME representative for help. 

Figure 4.  Registration buttons and indicators in base station 

Communicator ID display 

K1 switch 

RESET button 

CLEAR ALL REGISTRATION button 

START REGISTRATION button 

Status light 

Figure 3.  Wireless IQ™ and ionIQ™ base stations

 

If your base station looks like this 

see registration instructions on page 3 

ionIQ™ base station 

If your base station looks like this 

see registration instructions below 

Wireless IQ™ base station 

Содержание ion BP COM6100

Страница 1: ...arrow while you press the PWR button to turn off the HF mode Auto HF AHF Press and hold A1 or A2 and the Up arrow while you press the PWR button to turn the belt pac on in the Auto HF mode When you tu...

Страница 2: ...hold the B button on the belt pac while pressing and releasing the power button to turn the belt pac on and then release the B button or press the power button and hold it for approximately 10 second...

Страница 3: ...o unregister all of your belt pacs press the Clear All button on the REGISTRATION display and then press the Clear All button on the CLEAR ALL REGISTRATIONS display CAUTION When clearing all belt pacs...

Страница 4: ...to your collar and shirt to keep the cable safely behind you as shown in Figure 7 Hold the microphone boom at its base and adjust it so the microphone is near the side of your mouth Changing Batteries...

Страница 5: ...off when it stops transmitting Press and release A1 or A2 button if you want to speak to the customer again A single beep will be heard and green light on belt pac will come on when it begins transmi...

Страница 6: ...et by these reports and the FCC guidelines Hereby HM Electronics Inc declares that the COM6000 is in compliance with the essential requirements and other relevant provisions of R TTE Directive 1999 5...

Страница 7: ...ntages per the WEEE requirements Instructions for Disposal of WEEE by Users in the European Union The symbol shown below is on the product or on its packaging which indicates that this product was put...

Отзывы: