The content in this instruction manual (include accessories)
is kept the final modifying and explanation rights
Appliance is leaking
Slight leakage from the appliance pump is normal. If the
leakage increases contract the authorized customer
service.
Transport instruction
Mind the weight of appliance during moving. Put the appliance
a level ground. Pull out the telescopic rod (Max. length 410mm,
as pic D)to move the appliance.
Storage
1.Place the appliance on a level ground 2.Disconnect
trigger gun and high pressure hose 3.Disconnect
high pressure hose with outlet 4.Put the trigger gun
into the trigger gun holder 5.Wind back power cord
and high pressure
Please store the machine properly especially during winter
Technical specification
Working temp
!
5- 50 °C
Voltage
!
AC 220V
Weight
!
7.6Kg
Power
!
1700W
Length
!
294mm
Max.pressure
!
12.0Mpa
Width
!
293mm
Flow rate
!
380L/H
Height
!
548mm
Max.tap water
!
0 .4Mpa
Working pressure
!
8.0Mpa
Water temperature
!
0~ 40 °C