5 Technical Specifications

Classification: Switched-mode power supply power amp with limiters
All level indications refer to 0 dBV (1 V RMS).

Inputs

A, B Input
Sockets: XLR (1 = ground; 2 = +; 3 = --) and stereo 1/4" (tip = +; ring = --; sleeve = ground)
Type: Parallel electronically balanced 1/4" and XLR jacks 
Input impedance: 20 kOhms balanced, 10 kOhms unbalanced (VX 800: 22 kOhms balanced, 12 kOhms unba-
lanced)

Outputs

Channel A, B
Speakon

®

NL4 jacks and binding posts

Pin assignments: binding posts  red = +; black = --    /   Speakon

®

: 1+ = +; 1-- = -- ; 2+ and 2-- unconnected

Biamp/Bridge
Both power amp outputs routed to one Speakon

®

NL4 socket

Pin assignments:  1+ = Channel A+; 1-- = Channel A--;    /    2+ = Channel B+; 2-- = Channel B-

A special Speakon

®

cable must be used in bridge mode! Pin assignments for the bridge cable: 1+ amp = 1+

speaker; 2+ amp= 1-speaker,  the other two contacts must remain open or unconnected!

General

Controls: Master Power Switch, Input Sensitivity Knob, Operating Mode Switch, Internal Limiters, Ground-Lift.
Displays: On, Protect, Signal And Clipping LEDs.
Protective Circuits: Full DC fault, thermal and short-circuit protection
Cooling: Aluminum cooling element in ventilation channel, servo-controlled ventilator (air flow from front to
back)

Electrical Specifications

Frequency response: 20 Hz to 20000 Hz (±1 dB)
Crosstalk
-75 dB at peak level and 1 kHz (except VX 800: -80 dB)
-60 dB at peak level and 20–20000 Hz (except VX 800: -75 dB)
Signal to noise ratio: -103 dB at peak level (except VX800: -101 dB)
Damping factor: >600, 20–400 Hz with an 8-Ohm load
Rise time: 25 V/ms, 50 V/ms in Bridge Mode (except VX800: 20 V/ms / 40 V/ms)
CMRR @60 Hz: minimum of 48 dB, typically 56 dB (except VX 800: 54 dB/ 66 dB)

Power consumption
VX 800/1200: 1440 watts (IEC 60 065)
VX 2400/2402: 1800 watts (IEC 60 065)

VX_BDA_1_2a  21.08.2003 10:41 Uhr  Seite 8    (Schwarz Bogen)

Содержание VX SERIES

Страница 1: ...Manual 1 2 VX Power Amps English Deutsch Fran ais VX_BDA_1_2a 21 08 2003 10 41 Uhr Seite 1 Schwarz Bogen...

Страница 2: ...xposed to vibrations during operation Keep away from moisture and dust where possible Do not place the unit near water baths wash basins kitchen sinks wet areas swimming pools or damp rooms Do not pla...

Страница 3: ...ngineers inspect every amp when it comes off the assembly line and run computer tests on it Finally the power amps are subjected to a thorough endurance test under the harshest of conditions This is o...

Страница 4: ...he incoming signal out to more power amps We recommend that you use only balanced cabling for the input signals in order to avoid noise induced by electro magnetic fields and radio frequency inter fer...

Страница 5: ...he other two contacts must remain open or unconnected General Controls Master Power Switch Input Sensitivity Knob Operating Mode Switch Internal Limiters Ground Lift Displays On Protect Signal And Cli...

Страница 6: ...ch manuell und com putergesteuert berpr ft Zuletzt werden die fertigen Endstufen einer gr ndlichen Dauerpr fung unter h rtesten Bedingungen unterzogen So k nnen even tuell auftretende Abweichungen von...

Страница 7: ...r ein symmetrisches Kabel mit dem Eingang der Endstufe zu verbinden und am Ausgang der unsymmetrischen Quelle Pin 1 und Pin 3 des XLR Steckers bzw den Ring und den Schaft des Klinkensteckers zu verbin...

Страница 8: ...sregler Schalter f r Betriebsart interne Limiter Groundlift Anzeigen LEDs f r Ein Schutzschaltungen Signal und Clipping Schutzschaltungen Vollschutz f r Gleichspannung Temperatur und Last Ausgangskurz...

Страница 9: ...sance VX sont test s plusieurs reprises manuellement et par ordinateur pendant et apr s leur fabrication Enfin les tages de puissance termin s sont soumis un test prolong complet dans les conditions l...

Страница 10: ...dication est bien entendu fonction du type de signal d entr e En cas de signaux tr s faibles par exemple l tage de puissance peut tr s bien mettre un signal alors que la DEL Active n est pas encore al...

Страница 11: ...les pr sentes donn es valent pour tous les mod les Toutes les indications de niveaux se r f rent 0 dBV 1 V RMS Entr es A B Input Douilles XLR 1 terre 2 3 et jack st r o pointe anneau tige terre Conce...

Страница 12: ...OSE THIS APPLIANCE TO MOISTURE OR RAIN DO NOT OPEN CASE NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL SPEAKON PIN CONFIGURATION 1 1 CIRCUIT BREAKER B B MODE MONO STER...

Страница 13: ...o hkaudio com www hkaudio com International Inquiries fax 49 68 51 905 215 hkaudio intl musicandsales com Technische nderungen vorbehalten Copyright 2003 Music Sales GmbH 08 2003 MS D 0869 08 03 VX_BD...

Отзывы: