background image

ON

OFF

SWING

FAN

TEMP

TIMER

MODE

RESET CODE

LOCK

POWER/SOFT

AUTO

ON

OFF

H

A

B

i

on

COOL

DRY

HEAT

AIR FLOW SPEED SWITCH

TEMPERATURE INDICATOR

En-9

Parts and Functions

Wireless Remote Controller

OPERATION MODE
INDICATOR

AIR FLOW SPEED
INDICATOR

DESIGNATED
PERIOD INDICATOR

AIR FLOW DIRECTION
SWITCH

MODE SWITCH

indicates      the       current
operating  mode.

ON/OFF SWITCH

Indicates  the  air  flow speed
selected    by   the   air  flow
speed  switch.
When set at "AUTO",micro-
computer       selects      the
adequate    air   flow  speed
automatically   according  to
the  difference   between  the
designated temperature and
the room temperature.

Indicates  the  period  set  by
the  time  setting  switches.

Starts operation with a press;
stops operation with another
press.

Air   flow  direction   can  be
changed  vertically  (upward
and   downward )   by  each
press.

Used to select COOL,DRY
and HEAT operation.

The above example of indications is for the purpose of
explanation only and it is different from actual indications.

TIMER MODE INDICATOR

POWER MODE INDICATOR

TIME SETTING SWITCHES

SIGNAL SENDING HEAD

POWER MODE SWITCH

Sends signals to the remote
signal receiver of the indoor
unit.

Lights  up  when a signal is
sent to the indoor unit.

Indicates the temperature set
by  the  temperature  setting
switches.

OFF:  The   air  conditioner
stops  operation   after   the
designed  period.
On:The air conditioner starts
operation  after the designed
period.

Used to set soft or super
mode operation.

   :The indicated temperature
increases by 1°C(1.8°F) per
press.
   :The indicated temperature
decreases by 1°C(1.8°F) per
press.
When    the   switches   are
pressed  continuously ,  the
indicator changes quickly.

Used when setting the period
before the operation starts
or stops.

RESET

Used to reset the controller
back to normal condition.

Used to select TIMER ON,
TIMER OFF.

Used when adjusting the air
flow speed.

TIMER MODE SWITCH

TEMPERATURE
SETTING SWITCHES

AUTO

AUTO

HI

MED

LO

Used to lock the buttons and
LCD display.

LOCK INDICATOR

CODE INDICATOR

Used to send code A or B
with a press,A or B will be
displayed on LCD.Please
select A without special
explanation.

Note

:

There is no health function with these types.
Multi-split type has no power function.

SIGNAL   SENDING
INDICATOR

LOCK

CODE

Содержание HME 10 TW03 I/HOME 20 TW03 I

Страница 1: ... MANUAL FOR FUTURE REFERENCE No 0010548000 HSE 7 TW03 I HOE 7 TW03 I HSE 10 TW03 I HOE 10 TW03 I HSE 13 TW03 I HOE 13 TW03 I HSE 14 TW03 I HOE 14 TW03 I HSE 18 TW03 I HOE 18 TW03 I HME 10 TW03 I HOME 20 TW03 I PLEASE READ THIS OPERATION MANUAL BEFORE USING THE AIR CONDITIONER ...

Страница 2: ...HSE 7 TW03 I HOE 7 TW03 I HSE 10 TW03 I HOE 10 TW03 I HSE 13 TW03 I HOE 13 TW03 I HSE 14 TW03 I HOE 14 TW03 I HSE 18 TW03 I HOE 18 TW03 I HME 10 TW03 I HOME 20 TW03 I ...

Страница 3: ...Indoor Unit Outdoor Unit HSE 7 TW03 I HOE 7 TW03 I HSE 10 TW03 I HOE 10 TW03 I HSE 13 TW03 I HOE 13 TW03 I HSE 14 TW03 I HOE 14 TW03 I HSE 18 TW03 I HOE 18 TW03 I HME 10 TW03 I HOME 20 TW03 I ...

Страница 4: ...ONDITIONER Indoor Unit Outdoor Unit HSE 7 TW03 I HOE 7 TW03 I HSE 10 TW03 I HOE 10 TW03 I HSE 13 TW03 I HOE 13 TW03 I HSE 14 TW03 I HOE 14 TW03 I HSE 18 TW03 I HOE 18 TW03 I HME 10 TW03 I HOME 20 TW03 I PLEASE READ THIS OPERATION MANUAL BEFORE USING THE AIR CONDITIONER ...

Страница 5: ...En 2 Cautions Parts and functions Operation Maintenance Trouble shooting Contents 3 6 7 11 12 20 21 26 27 28 ...

Страница 6: ...pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center and contribute to environmental awareness by insisting on an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the ...

Страница 7: ... Applicable ambient temperature range 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agentor a similar qualified person The type of connecting wire is H05RN F or H07RN F 3 If the fuse on PC board is broken please change it with the type of T 3 15A 250V 4 The distance between the indoor unit and the floor should be more than 2m 5 The wiring method should be i...

Страница 8: ...ales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage CAUTION Installation in a inadequate place may cause accidents Do not install in the following place Connect the earth cable PROHIBITION PROHIBITION STRICT ENFORCEMENT earthing Do not install in the place where there is any possibility ...

Страница 9: ...RICT ENFORCEMENT Use an exclusive power source with a circuit breaker CAUTION Do not use for the purpose of storage of food art work precise equipment breeding or cultivation Take fresh air occasionally especially when gas appliance is running at the same time Do not operate the switch with wet hand Do not pour water onto the unit for cleaning Check good condition of the installation stand Do not ...

Страница 10: ...ndicator lights when timer switch of the remote controller is ON or OFF position POWER INDICATOR The power indicator lights when the ON OFF switch of remote controller is ON The opearation mode indicator lights when the air conditioner is in operation PAGE18 PAGE18 Indoor Unit For models The air flow direction can be adjusted with the vertical and horizontal louvers INLET GRILL MOLD PROOF AIR FILT...

Страница 11: ... For models En 8 Outdoor Unit For models For model For model HSE 18 TW03 I HOE 18 TW03 I For models OUTLET INLET DRAIN HOSE CONNECTING PIPING AND ELECTRICAL WIRING HOME 20 TW03 I HOE 13 TW03 I HOE 14 TW03 I HOE 7 TW03 I HOE 10 TW03 I ...

Страница 12: ...NDICATOR TIME SETTING SWITCHES SIGNAL SENDING HEAD POWER MODE SWITCH Sends signals to the remote signal receiver of the indoor unit Lights up when a signal is sent to the indoor unit Indicates the temperature set by the temperature setting switches OFF The air conditioner stops operation after the designed period On The air conditioner starts operation after the designed period Used to set soft or...

Страница 13: ...lay 13 TEMP display 14 DESIGNATED PERIOD diplay 15 POWER SOFT display 16 TEMP Used to select your desired temp 17 POWER ON OFF Used for unit start and stop 18 FAN Used to select fan speed LO MED HI AUTO 19 SWING Air flow direction can be changed by each press 20 POWER SOFT Used to select power or soft mode operation 21 LOCK Used to lock buttons and LCD display ion Brief Introduction to Health Oper...

Страница 14: ...d toward the remote signal receiver of the indoor unit Do not allow any obstacles between the signal sending head and the signal receiver The signal receiver may not receive the signal in a room which has an electro lighting rapid start type fluorescent lamp an inverter type fluorescent lamp or a cordless phone When attaching the wireless remote controller to a wall or post make sure that the indo...

Страница 15: ...d air filter as its front side faces to the front Operating without standard air filter may cause troubles with the machine Do not mistake the filter right and left for each of them are of different shapes 5 Close the Inlet Grille Close the Grille gently and surely Attachment of Air Purifying Filter Not to be injured by the edge of the metal fin heat exchange Activated carbon in the Air Purifying ...

Страница 16: ...ct the system Then the operation will start automatically after 3min If the system continues cooling or dry operation for a long period under high humidity the outlet may accumulate water and cause dew drops During dry mode operation the system performs the cooling operation until the room temperature reaches 33 8 O F above the designated temperature Then it continues dry mode operation intermitte...

Страница 17: ...e air conditioner does not start operation for approx 3min in order to protect the system Operation will start automatically after 3 min When the room temperature has not reached the required level because of a low ambient temperature add other heating facilities After replacing the dry batteries the operating conditions become ex factory preset as follows operation mode COOL temperature 26O C 78 ...

Страница 18: ... louver not work properly In order to move the vertical louver use remote controller without fail In case the louver does not work correctly once stop the operation and turn on again During cooling or dry operation the vertical louver should not be downward for a long time If this is done dew drops may appear at the outlet Even the louver directions is in the swing range the louver will move about...

Страница 19: ...imes until TIMER mode disappears Timer Cancellation 4 Press the ON OFF switch Make sure that the operating conditions are those desired Set the timer mode to OFF by pressing the timer mode switch Make sure that the timer mode indicator of the indoor unit lights up Set the operation period by pressing the time setting switches The operation period can be set from 1 hour to 12 hours by an hour 1 2 3...

Страница 20: ... disappears Timer Cancellation 4 Once the timer function is set the period is memorized From next time you can operate easily with operation of the ON OFF switch and the timer mode switch After replacing the dry batteries the designated period is set automatically as follows OFF 1 hour ON 6 hours Set the timer again if necessary If the power fails set timer again NOTICE Only some of the models hav...

Страница 21: ... the emergency or test operation is terminated When the remote controller is manipulated it gets the system back to the normal operation mode Test operation switch is the same as emergency switch Emergency operation Use this operation only when the remote controller is defective or lost When the emergency operation switch is pressed the Pi sound is heard once which means the start of this operatio...

Страница 22: ...inutes the air conditioner will automatically return to normal operation Press Power Mode Switch once The indication appears on the remote controller and the operation in Super Mode starts During the Super Mode operation the air flow speed is indicated Auto on the controller ON Press Power Mode Switch once The indication appears on the remote controller at one press and it goes out at the second p...

Страница 23: ...peration may not be powerful enough to keep the room temperature at the set level for as long time ON Press Power Mode Switch once The indication goes out at one press then the operation will returns to the regular operation OFF Press Power Mode Switch once The indication appears on the remote controller and the operation in Soft Mode starts During the Soft Mode operation the air flow speed is ind...

Страница 24: ...ir inlet or outlet Close doors and windows during operation Use the timer effectively Use the louvers effectively If the unit is not to be used for a long time turn off the power supply main switch During cooling operation prevent the penetration of direct sunlight with curtain or blind OFF Proper temperature ...

Страница 25: ...hed correctly that may cause defects Close the inlet grille 5 4 1 2 3 ON OFF SW IN G FA N TE MP TIM ER MO DE RE SE T CO DE LO CK POW ER SOF T A Once every two weeks En 22 Maintenance WARNING Before maintenance be sure to turn off the system and the circuit breaker Remote Controller Indoor Body Do not use water wipe the controller with a dry cloth Do not use glass cleaner or chemical cloth Wipe the...

Страница 26: ...le Cleaning Be sure to detach the inlet grille from the indoor unit when washing After washing wipe off the moisture completely from the inlet grille then dry it in the shade completely Moisture on the inlet grille may cause electric shock When detaching the inlet grille do not touch the metal fin of the unit to avoid the possibility of the injuries Cautions Attached the grille as before Keeping t...

Страница 27: ... front Operating without standard air filter may cause troubles with the machine Do not mix the filters right and left for each of them are of different shapes Do not get injured by the edge of the metal fin heat exchanger One set of the Air Purifying Filter standard air filter are consist of the two filters right and left 6 Close the Inlet Grille Close the Grille surely Please replace the air Pur...

Страница 28: ...ers prior to the operation Each of them are of different shapes Connecting the earthing cable EARTHING Do not block the air inlet or outlet Plug in Incomplete earthing may cause an electric shock After brush away dust at the plug insert the plug of the power supply cord into the outlet completely In case of using exclusive circuit breaker switch on the circuit breaker En 25 Maintenance ...

Страница 29: ...ing mold or bad smell be sure to operate at the designated temperature of 30O C cooling mode and High speed fan mode for 2 3 hours Take out the batteries from the remote controller 1 Put off the power supply cord 2 Cleaning the body 3 4 ON OFF SWING FAN TEMP TIMER MODE RESET CODE LOCK POWER SOFT A Maintenance En 26 ...

Страница 30: ...se see the trouble shooting in the next page Trouble Shooting Do not try to repair by yourself Improper repairs may cause the accidents or electric shock Warning NOTE The micro computer will stop the operation in self diagnosis mode Please aslo turn off the remote controller then When malfunction occurs in operation In case malfunction functions failure of no working or no reacting to remote contr...

Страница 31: ...ion air may not flow out to prevent excessive cooling During the heating operation air does not flow out until the air is heated enough to prevent cold air flow During the thawing in heating air may not flow During the dry mode operation and heating mode operation Air may not flow out The cooling heating function may not work effectively when the air filters are clogged with dust and dirt Make sur...

Отзывы: