ENGLISH
46
OPERATING TEMPERATURE
Cooling operation
Heating operation
Drying operation
Room temperature
17ºC ~ 32ºC
17ºC ~ 27ºC
10ºC ~ 32ºC
Outdoor temperature
0ºC ~ 50ºC
-15ºC ~ 34ºC
0ºC ~ 50ºC
Mode
Temperature
1-
Open and lift the front panel up to an angle until it remains
fixed with a clicking sound.
2-
One press of the manual control button will lead to the for-
ced AUTO operation.
3-
Close the panel firmly to its original position.
Manul operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted.
MANUAL OPERATION
To achieve optimal performance, please note the following:
•
Adjust the air flow direction correctly so that it is not directed on people.
•
Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels.
•
Close doors and windows on COOL or HEAT modes, or performance may be reduced.
•
Use TIMER ON button on the remote controller to select a time you want to start your air conditioner.
•
Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air conditioner
may stop running.
•
Clean the air filter periodically, otherwise cooling or heating performance may be reduced.
•
Do not operate unit with horizontal louvre in closed position.
OPTIMAL OPERATION
Panel
Manual
control button
AUTO/COOL
•
Once you push the manual button, the operation mode
is shifted in an order as: AUTO, COOL, OFF.
•
Push the manual button until the OPERATION indicator
flashes rapidly (five times per second), the unit now is
operating in forced COOL mode. This is used for testing
purposes only, .
•
When the OPERATION indicator goes off, the air condi-
tioner is OFF.
•
To restore the remote controller operation, use the
remote controller directly.
CAUTION
1-
If air conditioner is used outside of the above conditions, certain safety protection features may come into operation and
cause the unit to function abnormally.
2-
Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditio-
ner may attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set
HIGH fan mode.
3-
Optimum performance will be achieved within these operating temperature.
CAUTION