background image

En-11

To select SWING Operation

Press the SWING button (Fig. 5 

P

).

The SWING Display (Fig. 6 

\

) will light.

In this mode, the Air

fl

 ow Direction Louvers will swing automatically to direct the air

fl

 ow both up and down.

To stop SWING Operation

Press the SWING button (Fig. 5 

P

) once again.

The SWING Display (Fig. 6 

\

) will go out.

Air

fl

 ow direction will return to the setting before swing was begun.

Vertical Air Direction Adjustment

Press the SET button (Fig. 5 

Q

).

Each time the button is pressed, the air direction range will change as follows:

 1 

 2 

 3 

 4 

 5 

 6 

Types of Air

fl

 ow Direction Setting:

1, 2, 3, 4, 5, 6 : During Heating/Cooling/Dry modes

The Remote Controller's display does not change.

  Use the air direction adjustments within the ranges shown above.

 The vertical air

fl

 ow direction is set automatically as shown, in accordance with the 

type of operation selected.
  During Cooling/Dry mode : Horizontal 

fl

 ow 1

  During Heating mode 

: Downward 

fl

 ow 6

 During AUTO mode operation, for the 

fi

 rst a few minutes after beginning operation, 

air

fl

 ow will be horizontal 1; the air direction cannot be adjusted during this period.

 The 

air

fl

 ow direction setting will temporarily become 1 when the temperature of the 

air

fl

 ow is low at the start of the Heating mode.

Right-Left Adjustment

Adjust the Right-Left louvers.

 Move the Right-Left louvers to 

adjust air

fl

 ow in the direction you 

prefer.

ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical (up-down) direction of air

fl

 ow is adjusted by pressing the Remote Controller's SET button. Horizontal (right-left) air

fl

 ow direc-

tion is adjusted manually, by moving the Air

fl

 ow Direction Louvers.

Whenever making horizontal air

fl

 ow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are 

stopped.

 

DANGER!

 Never place fingers or foreign objects in-

side the outlet ports, since the internal fan 
operates at high speed, and personal injury 
could be caused.

  Always use the Remote Controller's 

SET button to adjust the vertical air

fl

 ow 

louvers. Attempting to move them man-
ually could result in improper operation; 
in this case, stop operation and restart. 
The louvers should begin to operate 
properly again.

  During use of the Cooling and Dry 

modes, do not set the Airflow Direc-
tion Louvers in the Heating range 
(4 - 6) for many hours, since water 
vapor may condense near the outlet 
louvers and drops of water may drip 
from the indoor unit. During the Cooling 
and Dry modes, if the Air

fl

 ow  Direction 

Louvers are left in the heating range for 
more than 30 minutes, they will auto-
matically return to position 3.

  When used in a room with infants, chil-

dren, elderly or sick persons, the air

fl

 ow 

direction and room temperature should 
be considered carefully when making 
settings.

 

CAUTION!

 When adjusting the Right-Left Louvers, it 

is necessary to stop the Vertical (up-down) 
louvers first and make sure that it stops 
completely before adjusting the direction.

1
2

3
4

5
6

Knob (2 places) 

Right-Left Louvers

Knob

SWING OPERATION

About Swing Operation

During Cooling/Dry mode  :  Swings between 1 and 3.(07/09/12 LEC), 1 and 3 .(14 LEC)
During Heating mode 

:  Swings between 3 and 6.(07/09/12 LEC), 4 and 6 .(14 LEC)

 The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when 

operating at very low speeds.

Begin air conditioner operation before performing this procedure.

9332428001_OM.indb   11

9332428001_OM.indb   11

1/7/2011   12:00:42 PM

1/7/2011   12:00:42 PM

Содержание 3NHY8690

Страница 1: ...h s i l g n E KEEP THIS MANUAL FOR FUTURE REFERENCE DIESE ANLEITUNG BITTE SORGF LTIG AUFBEWAHREN CONSERVEZ CE MODE D EMPLOI AFIN DE POUVOIR VOUS Y R F RER ULT RIEUREMENT GUARDE ESTE MANUAL PARA PODER...

Страница 2: ...burning smell etc immediately stop operation turn off the breaker and consult authorized service personnel In the event of refrigerant leakage be sure to keep away from fire or any flammables consult...

Страница 3: ...dry heating is switched auto matically to maintain the set temperature and the temperature is kept constant at all times SUPER QUIET OPERATION The indoor unit s airflow is reduced to produce quieter...

Страница 4: ...tion has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current operation Fig 6 Fig 2 Fig 3 Fig 4 Fig 5 93324280...

Страница 5: ...17 Auto Restart 7 ECONOMY Indicator Lamp green ECONOMY indicator lamp lights when ECONOMY OPERATION and 10 C HEAT OPERATION is operating 8 Intake Grille Fig 4 9 Front Panel 0 Air Filter A Airflow Dire...

Страница 6: ...Controller button again Remote Controller Holder PREPARATION CAUTION Take care to prevent infants from acciden tally swallowing batteries When not using the Remote Controller for an extended period re...

Страница 7: ...tton is pressed the fan speed changes in the following order AUTO HIGH MED LOW SUPER QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimal...

Страница 8: ...time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outdoor unit and its performance may be reduced In order t...

Страница 9: ...s can t be set simultaneously The function whose button on the remote controller is last pressed will be given priority POWERFUL Operation and OUTDOOR UNIT LOW NOISE Operation modes can be set simulta...

Страница 10: ...I Fig 5 J The indoor unit s TIMER Indicator Lamp orange Fig 3 6 will light 3 Use the SELECT buttons Fig 5 U to set the desired ON time OFF time 4 Press the OFF TIMER ON TIMER button Fig 5 J Fig 5 I 5...

Страница 11: ...the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in ac cordance with the set time setting When the set time...

Страница 12: ...never making horizontal airflow adjustments start air conditioner operation and be sure that the vertical air direction louvers are stopped DANGER Never place fingers or foreign objects in side the ou...

Страница 13: ...ature can be maintained at 10 C by pressing the 10 C HEAT button Fig 5 E so as to prevent the room temperature from falling too far To use 10 C HEAT OPERATION Press the 10 C HEAT button Fig 5 E The EC...

Страница 14: ...g sure the 2 lower tabs are returned prop erly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the indoor unit without Intake Grille installed Dust...

Страница 15: ...about every 3 years so as to maintain the deodorizing effect Filter frame is not a one off product Please buy delicated deodorizing filter UTR FA16 2 Sold separately when exchanging the filter Mainten...

Страница 16: ...n may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm...

Страница 17: ...conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recir culating air throughout the room with the result that some time may be required after firs...

Страница 18: ...9332428001_OM indb 17 9332428001_OM indb 17 1 7 2011 12 02 29 PM 1 7 2011 12 02 29 PM...

Страница 19: ...9332428001_OM indb 18 9332428001_OM indb 18 1 7 2011 12 02 29 PM 1 7 2011 12 02 29 PM...

Страница 20: ...9332428001_OM indb 19 9332428001_OM indb 19 1 7 2011 12 02 29 PM 1 7 2011 12 02 29 PM...

Отзывы: