26
MM06UE01-2002
Table 8.1
Fault table (continued)
Fault
Possible cause
Remedy
The forcer jerks while
moving and generates
operating noise that is not
caused by the profile
guideways
EMC interference in the encoder
signal, encoder cable plug
connection defective, pin bent in
plug
Place motor cable and/or encoder cable
shield in full contact with the earthing
terminal of the amplifier, check pin in plug
Position discrepancies after
several hours of operation
Use mains filter to stabilize voltage
9. Disposal
ATTENTION!
Danger caused by environmentally hazardous substances!
The danger to the environment depends on the type of substance used.
Clean contaminated parts thoroughly before disposal!
Clarify the requirements for safe disposal with disposal companies and, where appropriate, with
the competent authorities!
Table 9.1
Disposal
Fluids
Lubricants
dispose of as hazardous waste in an environmentally friendly way
Soiled cleaning cloths
dispose of as hazardous waste in an environmentally friendly way
Linear motor system
Cabling, electrical components
dispose of as electrical waste
PP components (e.g. cable chain)
dispose of separately
Steel components (e.g. guideways)
dispose of separately
Aluminum components (e.g. base)
dispose of separately