5
→
T
←
Tare
→
0
←
Zero
1.3 LED Error Code
Code
Meaning
OUEr
Weight > FS + 9d
–OUEr
Weight < -20d
Error
Calibration error
"
23.12
"
blink
Low battery warning (<10% of full charge) to recharge the battery
LLLLLL
In zeroing operation,weight<-2%FS
HHHHHH
In zeroing operation,weight>2%FS
2 Basic functions
2.1 Switching on
Press
ON
to switch on the indicator. The indicator displays the software version and performs
self-tests while displaying self-test patterns.
2.2 Switching off
Press
OFF
to switch off the indicator.
2.3 Weight unit
The weight unit is kg.
2.4 Zero
1. The display can be zeroed only when the weight is less than 2% of FS.
2. Unload the platform.
3. Press
0
to set the zero point and zero the display.
4. The zero status
0
is turned on.
2.5 Tare
2.5.1 Acquire tare
1. Tare can be set only after the display has been zeroed. Check to make sure zero status
0
is turned on.
2. Place the empty container on the platform.
3. Wait until the weight is stable when the stable status
is displayed.
4. Press
T
to set tare and zero the display.
5. The tare status NET is turned on.
6. The indicator switches to in net weight mode.
Содержание X1GM
Страница 2: ...Value Each Gram ...
Страница 11: ...Value Each Gram ...