background image

 

 

 9 

 

Byte No. 

Output format 

X1 

X2 

X3 

X4 

X5 

X6 

X7 

HEX 

3D 

35 

2E 

34 

33 

32 

31 

30 

2D 

Weight –1234.5 

– 

Adr = 99 output format 

Byte No. 

Output format 

X7 

X6 

X5 

X4 

X3 

X2 

X1 

HEX 

3D 

2D 

30 

31 

32 

33 

34 

35 

36 

Weight -1234.5 

– 

4.4  RS232 ASCII commands 

When the indicator address (Adr) is set to 01 to 98, Serial communication follows the Modbus ASCII 
protocol 

4.5  Printer format 

n = 3, gross = 88.69kg, tare = 29.41kg, net = 59.28kg 

No:XXXX                 No:   3 
G:XXXXXXkg         G: 88.69kg   
T:XXXXXXkg           T: 29.41kg 
N:XXXXXXkg           N: 59.28kg 

Accumulated weight 

No:XXXX                 No:   3 
W:XXXXXXXkg         W:  118.09kg 

5  Model Numbers 

Model 

Housing 

LCD 

IP65 

X3ARM 

Plastic 

Red 

No 

X3AGM 

Plastic 

Green 

No 

X3RM 

Stainless Steel 

Red 

No 

X3GM 

Stainless Steel 

Green 

No 

X3WRM 

Stainless Steel 

Red 

Yes 

X3WGM 

Stainless Steel 

Green 

Yes 

X5RM 

Stainless Steel 

Red 

No 

X5GM 

Stainless Steel 

Green 

No 

X1RM 

Plastic 

Red 

No 

X1GM 

Plastic 

Green 

No 

6  Services 

Services include a full range of technical on site services and workshop repair, preventative 
maintenance and calibration facilities. 

NOTE: Battery is not under warranty 

Содержание X1GM

Страница 1: ... ISO9001 registered company No 335 Haishen Xingxin Road Huinan Town Pudong District Shanghai 201301 China www hiweigh com All rights reserved specifications subject to change without notice Value Each Gram R X1 X3 A X5 RM GM Weight Indicator User Manual v 201802 ...

Страница 2: ...Value Each Gram ...

Страница 3: ...d for electrical and electronic equipment If you have any questions please contact the responsible authority or the distributor from which you purchased this indicator Should this indicator be passed on to other parties for private or professional use the content of this regulation must also be related The indicator has a rechargeable internal battery The battery contains heavy metals Please obser...

Страница 4: ...nt function Serial interface RS232 interface with continuous data output or command protocol Baud rate 1200 2400 4800 9600 Optional RS485 interface External AC adapter 100 240VAC 50 60Hz Rechargeable internal battery X3A R G M 6V 2 8AH X3 W R G M 6V 2 8AH X5 R G M 6V 2 8AH X1 R G M 6V 4AH Full charge battery operation X3A R G M 20 hours X3 W R G M 20 hours X5 R G M 20 hours X1 R G M 30 hours Full ...

Страница 5: ...ht is tare and display net weight 0 1 4 e weight 1 4 e LO set point A weight set point B OK set point B weight set point C HI set point C weight set point D kg Weight unit in kilogram 1 2 Keypad Keys Operation OFF Switch the indicator off ON Switch the indicator on Manual weight accumulation Proceed to next step Display weight to X10 resolution ...

Страница 6: ...tching off Press OFF to switch off the indicator 2 3 Weight unit The weight unit is kg 2 4 Zero 1 The display can be zeroed only when the weight is less than 2 of FS 2 Unload the platform 3 Press 0 to set the zero point and zero the display 4 The zero status 0 is turned on 2 5 Tare 2 5 1 Acquire tare 1 Tare can be set only after the display has been zeroed Check to make sure zero status 0 is turne...

Страница 7: ...the weight is stable when the stable status is displayed 3 Press to manually accumulate the weight and transmitted to RS232 port 4 The number of accumulation is displayed 5 Unload the sample so that the next sample can be accumulated 3 1 1 Query accumulated data Step Operation Display Description 1 Press n 1203 Display number of samples 2 Press T H 0 Display upper 4 digits of accumulated weight 3 ...

Страница 8: ...35 00 Use and T or 0 to enter set point D 35 00 11 Press 0 00 Return to weighing mode 3 3 High resolution display mode Press to display the weight in X10 resolution for 5 seconds The last digit of the decimal point will light 3 4 Automatic shutdown and power saving mode When the power saving mode is enabled If you do not operate within 30 seconds the indicator will enter a power saving mode The di...

Страница 9: ...in No PC DB9 Pin No 3 GND 5 GND 4 RxD 3 TxD 5 TxD 2 RxD 4 2 6 Connecting CN5A to a printer Indicator CN5A Pin No Printer DB25 Pin No 3 GND 7 GND 5 TxD 2 RxD 4 3 RS232 continuous ASCII output When the indicator address Adr is set to 00 or 99 the indicator continuously transmits the weight in RS232 ASCII data format LED display format Digit position X6 X5 X4 X3 X2 X1 Weight 1234 5 1 2 3 4 5 Adr 00 o...

Страница 10: ...re 29 41kg net 59 28kg No XXXX No 3 G XXXXXXkg G 88 69kg T XXXXXXkg T 29 41kg N XXXXXXkg N 59 28kg Accumulated weight No XXXX No 3 W XXXXXXXkg W 118 09kg 5 Model Numbers Model Housing LCD IP65 X3ARM Plastic Red No X3AGM Plastic Green No X3RM Stainless Steel Red No X3GM Stainless Steel Green No X3WRM Stainless Steel Red Yes X3WGM Stainless Steel Green Yes X5RM Stainless Steel Red No X5GM Stainless ...

Страница 11: ...Value Each Gram ...

Страница 12: ...upplier An ISO9001 registered company No 335 Haishen Xingxin Road Huinan Town Pudong District Shanghai 201301 China www hiweigh com All rights reserved specifications subject to change without notice Value Each Gram X1 X3 A X5 RM GM User Manual v 201802 ...

Отзывы: