9
Byte No.
1
2
3
4
5
6
7
8
9
Output format
=
X1
X2
X3
X4
X5
X6
X7
S
HEX
3D
35
2E
34
33
32
31
30
2D
Weight –1234.5
=
5
.
4
3
2
1
0
–
Adr = 99 output format
Byte No.
1
2
3
4
5
6
7
8
9
Output format
=
S
X7
X6
X5
X4
X3
X2
X1
HEX
3D
2D
30
31
32
33
34
35
36
Weight -1234.5
=
–
0
1
2
3
4
.
5
4.4 RS232 ASCII commands
When the indicator address (Adr) is set to 01 to 98, Serial communication follows the Modbus ASCII
protocol
4.5 Printer format
n = 3, gross = 88.69kg, tare = 29.41kg, net = 59.28kg
No:XXXX No: 3
G:XXXXXXkg G: 88.69kg
T:XXXXXXkg T: 29.41kg
N:XXXXXXkg N: 59.28kg
Accumulated weight
No:XXXX No: 3
W:XXXXXXXkg W: 118.09kg
5 Model Numbers
Model
Housing
LCD
IP65
X3ARM
Plastic
Red
No
X3AGM
Plastic
Green
No
X3RM
Stainless Steel
Red
No
X3GM
Stainless Steel
Green
No
X3WRM
Stainless Steel
Red
Yes
X3WGM
Stainless Steel
Green
Yes
X5RM
Stainless Steel
Red
No
X5GM
Stainless Steel
Green
No
X1RM
Plastic
Red
No
X1GM
Plastic
Green
No
6 Services
Services include a full range of technical on site services and workshop repair, preventative
maintenance and calibration facilities.
NOTE: Battery is not under warranty