background image

 

 

 

Please recharge the scale on time to protect the battery, and replace it if it runs out of life. 

The battery needs to be recharged every 3 months if it’s not used for long time. 

The replaced battery must be handled correctly. 

Please use the scale on the stable table or platform. 

Please don’t overload the scale 

 

1. MAIN SPECIFICATIONS 

Model 

CCX3|CSX3 

CCS3 

CCX6 |CSX6 

CSS6 

CCX15|CSX15 

CSS15 

CCX30 |CSX30 

CSS30 

Capacity 

3kg 

6kg 

15kg 

30kg 

Min. 

20e 

Readability 

0.1g 

0.2g 

0.5g 

1.0g 

Repeatability 

0.2g 

0.5g 

1g 

2g 

Model

 

CC715

 

CC730 | CC730B

 

CC760 |CC760B

 

CC7150B

 

Capacity 

15kg 

30kg 

60kg 

150kg 

Readability 

1g 

2g 

5g 

10g 

Repeatability 

1g 

2g 

5g 

10g 

Battery 

6V4Ah 

Accuracy 

Class III 

Pan Size 

CCX|CSX-220x310mm CSS-315x250mm CC7-300x400|400x500mm 

Working Temperature :     

-5-+35

 

Storage Temperature:   

 

-25-+ 50

 

Power:    

 

 

 

 

100-240V 50/60Hz – DC 12V/1Ah 12W 

Net Weight:     

 

 

 

3.8kg 

Power Consumption:   

 

12mA (backlight off) 

 

 

 

 

 

 

 

36mA (backlight on) 

 

 

 

 

 

 

 

48mA (backlight on and RS232 connected) 

Battery working time:  

 

320hrs (backlight off) 

 

2. DISPLAY 

 

Display of CSX and CSS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание CCS3

Страница 1: ...CSX CCX CSS CC7...

Страница 2: ...5 I9 57 F5A...

Страница 3: ...S30 Capacity 3kg 6kg 15kg 30kg Min 20e Readability 0 1g 0 2g 0 5g 1 0g Repeatability 0 2g 0 5g 1g 2g Model CC715 CC730 CC730B CC760 CC760B CC7150B Capacity 15kg 30kg 60kg 150kg Readability 1g 2g 5g 10...

Страница 4: ...Keypad of CSX and CSS Keypad of CC7 Display of CCX...

Страница 5: ...displayed weight value has to be less than 2 of maximum capacity Function 2 To move one space to the left or downward in setup mode Function 1 To subtract the container weight Function 2 To move one s...

Страница 6: ...ECF 2 Zero Calibration ECF 3 SPAN Calibration ECF 1 Weight Calibration 1 Press the key to start and go to the ECF 1mode and press the key to exit menu and back to weighing mode 2 Press the key 3 Use 0...

Страница 7: ...e key to exit menu and back to weighing mode 2 Use 0 9 keys to enter the weight to be calibrated and confirm with 3 Place the required weight mass onto the scale and press the key 4 Calibration proced...

Страница 8: ...e place the maximum weight on the pan high limit value press the key to confirm the high limit value Remove the weight from the pan from this moment the balance will beep and will show the message HI...

Страница 9: ...AoFF 01 The scale turns off automatically in 1 minute when the scale is not in operation AoFF02 The scale turns off automatically in 2 minutes when the scale is not in operation oFF 99 The scale turn...

Страница 10: ...2 Use 0 2 key to select backlight mode 3 Press the to confirm 4 To exit and return back to the weighing mode press the key UF 5 Accumulation Modes ACCU 0 0 A B A 0 Stable required 1 Stable not requir...

Страница 11: ...rate 2400 2 Baud rate 4800 3 Baud rate 9600 4 Baud rate 19200 B 0 RS232 output disable 1 Manual output Format 2 2 Stable output Format 1 3 Stream output Format 1 Communication Protocol UART signal of...

Страница 12: ...Stable NT Net Weight US Unstable GS Gross Weight Fixed 20 BYTES ASCII 1 2 1 1 2 1 1 2 3 4 5 6 7 8 1 2 3 4 1 2 Head 1 Head 2 Data Unit CR LF Output examples 1 Example 0 876 kg stable net weight S T N T...

Страница 13: ...W 1 1 0 0 0 g T W 0 0 g P T W 1 0 0 0 g N W 1 0 0 0 0 g A P W 1 0 0 0 0 0 g Q T Y 1 0 0 0 p c s Press the key for 3 seconds key to output T I 2 T W 2 0 0 0 0 g T Q 2 0 0 0 p c s 1 Press the key to acc...

Страница 14: ...ng mode press the key UF 8 Display Condition at Zero ZP 0 Off ZP 1 One division not to display at zero ZP 2 Two division not to display at zero ZP 3 Three division not to display at zero ZP 4 Four div...

Страница 15: ...5 I9 57 F5A...

Страница 16: ...CCX CSX CSS CC7...

Отзывы: