background image

Number of pieces setup

Use the 0-9 numbers keys to input the desired sample quantity, when the 
display  weights  shows  the  weight,  press  the 

  key,  the  piece  weight 

window  shows  the  unit  weight  and  total  count  window  displays  the  total 
pieces number.

Limits function

Place the items to be counted on the weighing pan, use the 0-9 number keys 
to introduce the number of pieces loaded and press the 

 key. Once the 

balance memorizes the sample, place the maximum weight on the pan (high 
limit value), press the 

 key to confirm the high limit value.

Remove the weight from the pan, from this moment, the balance will beep and 
will show the message 

“HI” 

when the load will excess the preset high value.

FUNCTIONS SETUP

To access the configuration functions, press the keys 

 and 

.

          

UF-1 Internal Value / Display Battery Voltage

1.  Press the 

 key to display the following internal values:

·  The Weight / Peso display shows internal value of the span.

·  The Unit Weight / Peso Unit display shows the current battery voltage.

·  The Count parts / Piezas display shows the internal value (zero).

2.  Press the 

 key to exit menu.

Содержание CCS3

Страница 1: ...CSX CCX CSS CC7...

Страница 2: ...5 I9 57 F5A...

Страница 3: ...S30 Capacity 3kg 6kg 15kg 30kg Min 20e Readability 0 1g 0 2g 0 5g 1 0g Repeatability 0 2g 0 5g 1g 2g Model CC715 CC730 CC730B CC760 CC760B CC7150B Capacity 15kg 30kg 60kg 150kg Readability 1g 2g 5g 10...

Страница 4: ...Keypad of CSX and CSS Keypad of CC7 Display of CCX...

Страница 5: ...displayed weight value has to be less than 2 of maximum capacity Function 2 To move one space to the left or downward in setup mode Function 1 To subtract the container weight Function 2 To move one s...

Страница 6: ...ECF 2 Zero Calibration ECF 3 SPAN Calibration ECF 1 Weight Calibration 1 Press the key to start and go to the ECF 1mode and press the key to exit menu and back to weighing mode 2 Press the key 3 Use 0...

Страница 7: ...e key to exit menu and back to weighing mode 2 Use 0 9 keys to enter the weight to be calibrated and confirm with 3 Place the required weight mass onto the scale and press the key 4 Calibration proced...

Страница 8: ...e place the maximum weight on the pan high limit value press the key to confirm the high limit value Remove the weight from the pan from this moment the balance will beep and will show the message HI...

Страница 9: ...AoFF 01 The scale turns off automatically in 1 minute when the scale is not in operation AoFF02 The scale turns off automatically in 2 minutes when the scale is not in operation oFF 99 The scale turn...

Страница 10: ...2 Use 0 2 key to select backlight mode 3 Press the to confirm 4 To exit and return back to the weighing mode press the key UF 5 Accumulation Modes ACCU 0 0 A B A 0 Stable required 1 Stable not requir...

Страница 11: ...rate 2400 2 Baud rate 4800 3 Baud rate 9600 4 Baud rate 19200 B 0 RS232 output disable 1 Manual output Format 2 2 Stable output Format 1 3 Stream output Format 1 Communication Protocol UART signal of...

Страница 12: ...Stable NT Net Weight US Unstable GS Gross Weight Fixed 20 BYTES ASCII 1 2 1 1 2 1 1 2 3 4 5 6 7 8 1 2 3 4 1 2 Head 1 Head 2 Data Unit CR LF Output examples 1 Example 0 876 kg stable net weight S T N T...

Страница 13: ...W 1 1 0 0 0 g T W 0 0 g P T W 1 0 0 0 g N W 1 0 0 0 0 g A P W 1 0 0 0 0 0 g Q T Y 1 0 0 0 p c s Press the key for 3 seconds key to output T I 2 T W 2 0 0 0 0 g T Q 2 0 0 0 p c s 1 Press the key to acc...

Страница 14: ...ng mode press the key UF 8 Display Condition at Zero ZP 0 Off ZP 1 One division not to display at zero ZP 2 Two division not to display at zero ZP 3 Three division not to display at zero ZP 4 Four div...

Страница 15: ...5 I9 57 F5A...

Страница 16: ...CCX CSX CSS CC7...