HT(HPC)-100CT-2 Series
HITROL CO., LTD. 6
Dielectric Constant Value
Fuel Oil (Gasoline, Diesel…)
2
Hydrogen chloride
4.6~12
Hexane, Liquid
6
Butanol
17~18
Ammonia
16~25
Alcohol
16~31
Acetone
20
Caustic soda
22~26
Ethanol
25
Methanol
32~33
Glycerin
47~68
Water
81
Sulfuric acid
84
The data of dielectric constant value can be downloaded from technical data by accessing our
website
Rod Probe
Rod Probe w/
Ground Rod
Rod Probe w/
Ground Tube
Wire Probe
Wire Probe
w/ Ground Wire
Total length (L)
100~3,000
100~3,000
100~3,000
1,000~15,000
1,000~15,000
Probe dia.
Ф15
Ф15
Ф15
Ф4
Ф4
Ground dia.
-
Ф10
Ф27.2
-
Ф4
For acid liquids
O
O
-
O
O
For high-viscosity
liquids
O
O
-
-
-
For non-metal
tanks
-
O
O
O
For sphere tanks
-
O
O
-
O
Содержание HPC-100CT-2 Series
Страница 13: ...M 100CT2 User Manual Capacitance Type Level Transmitter Doc no Rev1 3 Issued Date 2021 07 15 APPENDIX V ...
Страница 15: ...2 Specification Table 1 Specification ...
Страница 16: ...3 Configuration of Setting Menu Table 2 Setting Menu List ...
Страница 17: ...4 Setting and Operating LCD Configuration Into the Setting Menu Return to Setting Mode ...
Страница 18: ... Select the Setting Menu Change the User Setting Table 3 Key Button Guidance ...
Страница 20: ... Zero Span Capacity fine Adjustment Zero Setting Span Setting Span Setting Other ...