HCC(HPC)-95R Series
HITROL CO.,LTD. 9
Wiring and
AMP
Setting
- Connect AC (110/220 V) or DC (24 V) according to the power specifications.
- Make sure to connect the power with the correct polarity (+, -).
- Do not connect the wire with the power connected.
- This product provides SPDT, DPDT. Wire it with COM and NO terminal
to use HIGH contact.
- Make sure to connect it to an external ground.
- Measure the safety after installing the product.
- Set Fail Safe Mode to H.
- Turn on the power.
- Set the Sensitivity Volume to the center and select range S/W (10~90PF),
(65~150PF), (120~260PF) to place the Red LED On / Off between the center
and H of the Sensitivity volume.
- Red LED should be On when the probe touches the work piece.
- Fail Sage Mode to L when using for the lower limit.
(The product is set for the upper limit when the product is shipped.)
■
Unit Composition and Designation
- HLC-95R-P
1.
Terminal
2.
Contact Output Terminal
3.
Power Input Terminal
4.
Fail Safe Mode
5.
Relay Action LED(Green)
6.
Detect LED(Red)
7.
Range Set
8.
Sensitivity Aduj.
9.
Time Aduj (0~30sec.)
Range Set