■ Cautions for Use 

Make sure to connect the product and container using the required tools. 

Store the key safely and make sure that it is locked. 

Do not apply high impact to the product. 

■ Disposal   

Make sure to separate the AMP and main unit from the housing before 

wasting it. No part affects the environment so no special attention 

is required (e.g., mercury switch). 

 

■  Label 

The label is attached on the housing to state the model, serial number, working temperature, 

working pressure, and output. The serial number is a unique manufacturing number.

 

 

Do not apply a non-ex-proof product in an ex-proof zone.   

An ex-proof product can be used where the environment and liquid of   

the containers are type 1 and 2. 

 

<Weather-Proof > 

<Ex-Proof> 

Understand the aforementioned and never measure any general-type liquid exceeding 80℃ 

and  150℃  for  the  high-temperature  type.  Also,  keep  the  ambient  temperature  of  the 

housing in the -20 - +60℃ range. 

An  ex-proof  product  is  a  pressure-resistance and  ex-proof  type, so  do  not open the  cover 

while using it. 

The ex-proof product is designed according to Articles 34 and 4 of Article 58, 

Occupation Safety and Health Act.   

 

Содержание HCC-95R Series

Страница 1: ...R D INSTITUDE HITROL CO LTD 141 Palhakgol road Jori eup Paju si Gyeonggi do Korea TEL 00 82 31 950 9700 FAX 00 82 31 943 5600 www hitrol com INSTRUCTION MANUAL CAPACITANCE TYPE LEVEL SWITCH HCC 95R Se...

Страница 2: ...onent and Technical Data 6 Attachment and Cautions 8 Wiring and AMP 9 Setting 9 Removal Cautions 10 Cautions for Inserted External Wire 10 Ex Proof Product Cautions for Grounding 10 Ex Proof Product S...

Страница 3: ...t an object to be measured in a tank using its dielectric constant It can be installed on the top or side of a tank and it is easy to adjust and use with corrosive fluid making it applicable to differ...

Страница 4: ...16L with TEFLON Process Connection PT 1 M Screw Housing Cable Entry AL PF3 4 F IP65 Ex Proof Version Model HPC 95R HPC 95RH HPC 95RW HPC 95RWH Probe Type Rod Rope Mounting Screw Flange Ambient Tempera...

Страница 5: ...12V 6 Power State LED Green 7 Operating Temperature 20 70 8 Dimension 80mm x 65mm x 20mm 9 Weight 50g Combination Unit Model HLC 95R L HLC 95R P Installation Local Panel inside Ambient Temperature 20...

Страница 6: ...Std NPT 1 PF 1 Other Flanges ANSI JIS DIN Tri Clamp Material 316L Other Active Rod material 316L With Teflon Weisht material C S 316L Housing Connection Probe High Temp Version High Temp Version Mater...

Страница 7: ...it out website www hitrol com and download from Technical Data For Liquids For Solids Rod Probe Rod Probe Fully insulated TEFLON Rod Probe Rope Probe Total length L 100 2 500 300 1 000 100 2 500 Min 1...

Страница 8: ...th low dielectric constant To install 2 or more level switches in one container keep 300m or more between probes If the gap is smaller between probes they may interfere each other causing instability...

Страница 9: ...t Set Fail Safe Mode to H Turn on the power Set the Sensitivity Volume to the center and select range S W 10 90PF 65 150PF 120 260PF to place the Red LED On Off between the center and H of the Sensiti...

Страница 10: ...ndings For the external grounding the ground wire must be 4 mm2 4 mm SQ An internal ground wire must have the same size as the power line The size of an internal grounding terminal lug must be 3 1 mm2...

Страница 11: ...serial number working temperature working pressure and output The serial number is a unique manufacturing number Do not apply a non ex proof product in an ex proof zone An ex proof product can be use...

Страница 12: ...1 Palhakgol road Jori eup Paju si Gyeonggi do Korea TEL 031 950 9700 Headquarters and A S FAX 031 943 5600 Headquarters and A S Inspection The sensor and transmission parts of a capacitive level trans...

Отзывы: