Installation
12
HT800 Series VTR and Disk controller
CUE In - cues the VTR to the last entered cue
location.
VTR - outputs a trigger when a different VTR is
selected.
Out-5s – outputs a trigger pulse 5 seconds before the
mark out point.
Out-0s – outputs a trigger pulse at the mark out
point.
GPIs are independent and can be set specifically to
any VTR. Select the VTR first before assigning the
GPI function, the selected VTR then has that GPI or
GPIs assigned to it. The menu will display all trigger
settings but there is no indication as to which trigger
is assigned to which VTR.
Using the on-air tally
The red on-air tally light on the controller is set from
Trig A. Please refer to the Trig A, B, C, D Engineering
Menu command in Chapter 4 for further details.
Using additional controllers
The LOOP RJ45 socket can be used to connect an
additional remote controller or automation system,
which may be assigned using the HT controller to any
VTR or device emulating a VTR.
The HT8821/M adapter can be supplied for this
purpose.