47
+
INC
–
DEC
+
INC
–
DEC
Start
Enter
Batt type
stop
> 3 seconds
Battery
Type
Elapsed
Time
Charge
Current
Charged
Capacity
Battery
Voltage
Start
Enter
Batt type
stop
+
INC
> 3 seconds
Elapsed
Time
Discharged
Capacity
Battery
Voltage
Discharge
Current
Battery
Type
–
DEC
+
INC
–
DEC
PROGRAM SELECT
SYSTEM SETUP
Synchron enable?
ON/OFF
Professional Balance Charger, Discharger
Hochleistungs Profi Balance
LADER / ENTLADER
9.1. Charging Lead Acid (Pb) Batteries
9.2. Discharging Lead Acid (Pb) Batteries
10. Synchronous Mode
Set the charge current on the left and the nominal voltage
on the right. Charge current can be set from 0.1-6.0 A. The
voltage must match the battery being charged. Press the
„START/ENTER“
key for more than 3 seconds to start
charging.
The screen will display the real-time charging status. Press
the
„START/ENTER“
key to alter the charge current. Press
the
„START/ENTER“
key again to store the parameter
settings you set. Press the
„BATT TYPE/STOP“
key to end
the program.
Set up the discharge current on the left and the nominal
voltage on the right. The discharge current can be set from
0.1-5.0 A. The voltage should match the battery being
charged. Press the
„START/ENTER“
key for more than 3
seconds to start discharging.
The screen displays the real-time discharging status. Press
the
„START/ENTER“
key to alter the discharge current. Press
the
„START/ENTER“
key again to store the parameter
value you set. Press the
„BATT TYPE/STOP“
key to end the
program.
When charging two same batteries, both charging channels
can be set by channel one. ON/OFF Process:
Press
„INC/DEC“
to choose.
Press
„START“
to enter the System Setting, then press
„INC/DEC“
to choose.
Press
„START“
, ON/OFF will blink, Then press
„INC/DEC“
to choose ON or OFF. Press
„START“
again to confi rm.
Press
„STOP“
to exit program setting, Press
„INC/DEC“
to
choose the battery type, both channels will be charging at
the same time with same charging info.