1-9-17
1-9-18
1-9-19
WF1
TP751
V-OUT
TP752
A-OUT
WF2
TP302
RF-SW
TP301
C-PB
S-INH
VR501
SW-P
WF5
TP303
CTL
TP510
LD-SW
TP502
CAUTION !
Fixed voltage power supply circuit is used in this unit.
If Main Fuse (F001) is blown, check to see that all components in the power supply circuit
are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
NOTE :
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT , AN ISOLATION TRANSFORMER MUST BE USED.
ALSO , IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY , WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT , A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE FUSE.
ATTENTION : POUR UNE PROTECTION CONTINUE LES RISQES
D'INCELE N'UTILISER QUE DES FUSIBLE DE MEMO TYPE.
RISK OF FIRE-REPLACE FUSE AS MARKED.
"This symbol means fast operating fuse."
"Ce symbole reprèsente un fusible à fusion rapide."
A V
F
Main CBA Top View
Содержание VT-FX685A
Страница 23: ...1 9 3 1 9 4 1 9 5 Main 1 4 Schematic Diagram PWR VCR PM REC ...
Страница 24: ...1 9 6 1 9 7 1 9 8 Main 2 4 Schematic Diagram ...
Страница 26: ...1 9 11 1 9 12 Main 4 4 Schematic Diagram ...
Страница 27: ...1 9 13 1 9 14 Function Schematic Diagram ...
Страница 28: ...Function CBA Top View Function CBA Bottom View 1 9 15 1 9 16 ...
Страница 54: ... 48 49 S 17 Slide Holder S Slide Holder T S 18 50 L 3 Fig DM17 52 51 Slide P 9 Fig DM18 2 4 8 ...
Страница 58: ...EXPLODED VIEWS Front Panel A1X 3 1 1 ...
Страница 67: ...VT FX685A VT FX685AC Digital Media Products Division Tokai VT FX685A FX685AC VT FX685A FX685AC No 5102E TK ...