High Speed Dome Camera User’s Manual
- 43 -
Appendix C 24VAC Wire Diameter and Transmission Distance Comparison Chart
While the wire diameter determinate and 24VAC loss rate under 10%, the longest transmission distance is recommended as
following chart.
Wire diameter (mm)
Transmission
Distance
feet(m)
Power[VA]
0.8000
1.000
1.250
2.000
10
283 86
451 137
716 218
1811 551
20
141 42
225 68
358 109
905 275
30
94 28
150 45
238 72
603 183
40
70 21
112 34
179 54
452 137
50
56 17
90 27
143 43
362 110
60
47 14
75 22
119 36
301 91
70
40 12
64 19
102 31
258 78
80
35 10
56 17
89 27
226 68
90
31 9
50 15
79 24
201 61
100
28 8
45 13
71 21
181 55
110
25 7
41 12
65 19
164 49
120
23 7
37 11
59 17
150 45
130
21 6
34 10
55 16
139 42
140
20 6
32 9
51 15
129 39
150
18 5
30 9
47 14
120 36
160
17 5
28 8
44 13
113 34
170
16 4
26 7
42 12
106 32
180
15 4
25 7
39 11
100 30
190
14 4
23 7
37 11
95 28
200
14 4
22 6
35 10
90 27
Table 5